![4ms Sampler User Manual Download Page 16](http://html.mh-extra.com/html/4ms/sampler/sampler_user-manual_3044921016.webp)
[AUTO STOP ON SAMPLE CHANGE]
Possible values:
Yes
,
No
,
Looping Only
Default value:
Yes
Yes:
changing to a new sample always stops/restarts playback
No
: changing to a new sample never interrupts playback
Looping Only
: changing to a new sample restarts playback only when looping
[PLAY BUTTON STOPS WITH LENGTH AT FULL]
Possible values:
Yes
,
No
Default value:
Yes
Yes
:
Play
buttons act as start/re-start, unless
Length
is at 100%, then they act as start/stop
No
:
Play
buttons always act as start/re-start sample
[QUANTIZE CHANNEL 1 1V/OCT JACK]
Possible values:
Yes
,
No
Default value:
No
Whether or not the
Pitch
CV jack is quantized to semitones
[QUANTIZE CHANNEL 2 1V/OCT JACK]
Not used on the
Sampler
[SHORT SAMPLE PERCUSSIVE ENVELOPE]
Not used on the
Sampler.
Percussive envelopes can be disabled by setting FADE TIME to 0.
[CROSSFADE SAMPLE END POINTS]
Not used on the
Sampler.
Crossfading can be disabled by settings FADE TIME to 0 (see below).
[STARTUP BANK CHANNEL 1]
Possible values: any number from 0 to 59, specifying which bank to jump to when powering up.
The ones digit of the bank number equals color of the bank, with 0 = White, 1 = Red, … 9 = Pearl.
The tens digit of the bank number equals the number of blinks (ranging from 0 to 5).
Therefore 3 means Yellow (no blinks), and 41 means Red-4 (four blinks).
[STARTUP BANK CHANNEL 2]
Not used on
Sampler
[TRIG DELAY]
Possible values: any whole number between 1 and 20, which sets the trigger delay in milliseconds.
Default: 8 (which is 8ms).
This is the amount of delay automatically added after a trigger is received on the
Play/Rec
trigger
jack, before the
Pitch
CV and
Start Pos
CV jacks are read and the sample is played. This delay allows
the
Sampler
to work with sequencers and keyboards which output a gate before the CV stabilizes at a
voltage.
[FADE TIME]
Possible values: any number between 0 and 255 which translates to a fade time in milliseconds. The
value of 0 means no crossfading will happen.
Default: 24 (which is 24ms).
See the section
Adjustable Fade Time
on page 15 for an explanation of this feature.
This value can also be controlled on the
Sampler
by holding
Reverse
and turning
Length
.
[AUTO INCREMENT REC SLOT ON TRIG]
Not used on the
Sampler
(future firmware version will support it).