11
UP
RADIO SET
FORCE
1. With both “UP” and “DOWN” LEDs are on after limit-setting, press the “FORCE”
button once to enter Sensitivity Auto-Learning mode.
Following limit-setting, the unit is now ready to learn the sensitivity for door
travel automatically. Proceed with the following steps to complete installa-
tion.
2. The door will open and stop at UP limit for 2 seconds.
3. Door will then close and stop at down limit. The operator will beep 3 times, sen-
sitivity is learnt automatically, acknowledging that the sensitivity has been set.
X3
S
ENSITIVITY
A
UTO-
L
EARNING