PAGE 10
TROUBLESHOOTING GUIDE
FAULT
REMEDY
Unexpected Operation
Re-calibrate sensor, if problem continues contact 4B.
False / Inconsistent Readings
1. Check that sensor is not in the direct flow of material, and
remove from flow if necessary.
2. If sensor is coated in dust, re-calibrate by following calibration
instructions.
Sensor Not Detecting Material
1. If monitoring different types of materials, calibrate the sensor
sensitivity to the lightest material being monitored.
2. Re-calibrate sensor, if problem continues contact 4B.
BINSWITCH ACCESSORIES
BMPA MOUNT
Urethane compression
fitting mount with 1-1/4”
NPT external thread
BAS ABRASION SHIELD
Urethane abrasion shield
mount for high-abrasion or
liquid applications
SMP MOUNTING PLATE
Zinc plated steel with 1-1/4”
NPT coupling (available in
stainless steel)
BMPG36 GLAND MOUNT
Plastic gland mount
BSM3 CLAMP MOUNT
HDP clamp style mount
A34NPT CONDUIT ADAPTER
Anodized aluminum 30 mm to
3/4” NPT conduit adapter