Windows NT®4.0 Installation
www.3ware.com
73
(the disk on the lower channel number) being copied to the other
drive. In RAID 10 arrays, data from one half of the array is copied
to the other half. After the initial verification, subsequent verifies to
a RAID 1 or 10 array result in the data from one drive (or set of
drives) being compared to the other drive (or set of drives).
RAID 5 arrays are immediately initialized after being created in the
BIOS by writing zeroes to all array members. The user can reboot
the system before this is complete in order to use the RAID 5 array
immediately. Once booted to the operating system, the RAID 5
array goes into initialization mode after a delay of up to ten min-
utes. The advantage of this procedure is that the RAID 5 array can
be used immediately, but it will not be fault tolerant until the initial-
ization is complete. The disadvantage of this is that it takes longer
for the array to become fully redundant, because it takes longer to
initialize an array than it does to write zeroes to the array.
Install the 3DM disk management utility
Refer to the
3DM Disk Management Utility
chapter.
Summary of Contents for 7000-2 - Escalade RAID Controller
Page 10: ...3ware Escalade ATA RAID Controller User Guide x...
Page 32: ...3ware Escalade ATA RAID Controller User Guide 32 www 3ware com...
Page 99: ......
Page 120: ...3ware Escalade ATA RAID Controller User Guide 120 www 3ware com...
Page 159: ...Checking Array Status www 3ware com 159 Figure 53 3DM Settings Display...
Page 165: ...Configuration and Array Maintenance Settings www 3ware com 165 Figure 56 3DM Configure Display...
Page 170: ...3ware Escalade ATA RAID Controller User Guide 170 www 3ware com Figure 57 3DM Help Display...
Page 188: ...3ware Escalade ATA RAID Controller User Guide 188 www 3ware com...
Page 194: ...3ware Escalade ATA RAID Controller User Guide 194 www 3ware com...