Inspect the site to determine the appropriate location for the SmartRecorder installation. Ensure that the
1.
environmental conditions listed below are satisfied; mounting the unit in a location which exceeds the
conditions listed below will void its warranty.
Environmental Conditions
Operating Temperature
5° to 35°C (41° to 95°F)
Heat Dissipation
1360 BTU/Hour
Humidity
5% to 95% RH (noncondensing)
Storage Conditions
-10° to 60°C (14° to 140°F)
Maximum Operating Altitude
3,048 m (10,000 ft)
Clearance
A minimum of 4” clearance in both front and rear of unit.
Connect the power cable.
4.
Connect a network cable to the
5.
left
(primary)
Ethernet port.
If you will be connecting to the SmartRecorder with a monitor, mouse, and keyboard:
Once a suitable location has been identified,
2.
attach the rack-mount ears to the server using
the included screws.
Mount the unit in the equipment rack or shelf.
3.
Connect the keyboard to the purple
6.
port and the mouse to the green
port.
Connect a monitor to the monitor
7.
port.
Press the power button on the front
8.
of the unit.
If you will be configuring the system with a laptop and network cable or USB network adapter:
See
Appendix B: Connecting a Laptop to a 3VR SmartRecorder
for complete instructions.
primary
Ethernet port
Chapter 1: Installing a 3VR SmartRecorder
13