background image

2

TABLE OF CONTENTS

3T-MOTORS

 

Shutter motors / Awning motors

 

with eletronical limit switches

Guideline / Determine torque

 

 

Page 3 

 Safety instructions 

 

 

Page 4

 Function overview

Scope of delivery 

 

 

 

Page 5

Technical 

data 

   Page 

5

 Installation notes 

 

 

Page 6

 Installation instructions  

 

Installation shutter motor 

 

 

Page 7 – 12

 Installation situation  

 

 

Page

 7

 1) Prepare power connection 

  Page 

7

 2) Select motor bearing 

 

 

Page 7 – 8

 3) Remove shutter shaft   

 

 

Page 9

 4) Prepare motor for installation   Page 

9

 5) Mount 

bearings 

   Page 9

 6) Mount motor with shaft unit   

 

Page 9 – 10

 7) Shutter motor wiring 

 

 

Page 10

 8) Setting the end positions   

 

Page 11

 Mounting instructions for motor type 3T35-B 

Page 12

Installation awning motor 

 

 

Page 13 – 15

 1) Preparation 

   Page 13

 2) Prepare motor for installation  

 

Page 13

 3) Mounting awning motor 

 

 

Page 13 – 14

 4) Awning motor wiring 

 

 

Page 14

 5) Setting the end positions   

 

Page 15

 Troubleshooting

What to do when ...   

 

 

Page 16

 EU Declaration of Conformity

   

Page 17

 

Optional accessories tubular motors

 

Page 18 – 19

 Hotline

06732 600 0369

  

CONTACT

3T-Components GmbH & Co. KG

Bahnhofstr. 34
55578 Wallertheim

Email:

 [email protected]

Tel:

 +49 (0) 6732-600 03 69

Fax:

 +49 (0) 6732-600 54 30

Opening hours:

Monday – Friday
8:00 – 17:00

www.3t-components.de

Learn more about us:

3T-MOTORS Tubular motors

  |  Table of contents

© Copyright notice

All contents of these instructions, in particular texts, photographs and graphics, 
are protected by copyright. Unless expressly indicated otherwise, the copyright 
is held by 3T-Components GmbH & Co. KG. Please ask us if you wish to use 
the contents of this document.

Summary of Contents for 3T-MOTORS 3T45-10B

Page 1: ...B For shafts from 40 mm 3T35 10B 3T35 13B www 3t components de WEEE Reg Nr DE 77028333 INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS INSTALLATION OPERATING INSTRUCTIONS Instructions and notes...

Page 2: ...ning motor Page 13 15 1 Preparation Page 13 2 Prepare motor for installation Page 13 3 Mounting awning motor Page 13 14 4 Awning motor wiring Page 14 5 Setting the end positions Page 15 Troubleshootin...

Page 3: ...account rail guidance of approx 10 Roller shutter area m x Weight roller shutter material m Weight roller shutter kg 10 Friction losses Required traction force kg Example PVC Roller shutter area 3 00...

Page 4: ...mains connection cable of the drives must be laid internally in the empty conduit up to the junction box The local electrical regulations must be observed For the electrical connection of the tubular...

Page 5: ...230 V 608 mm 587 mm 3 m 4 min IP44 4260601761380 3T45 20B 20 Nm 40 kg 6 m 4 7 m 161 W 15 U min 22 U 230 V 608 mm 587 mm 3 m 4 min IP44 4260601761397 3T45 30B 30 Nm 60 kg 9 m 7 m 200 W 15 U min 22 U 2...

Page 6: ...mm SW40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Grinding marks of any kind on the motor housing will void the warranty The inspection...

Page 7: ...5 B and 3T35 B Universal bearing and cover cap bearing 3T45 30B 3T45 40B clip bearing Use one of the two motor bearings depending on the installation situation 1 2 3 4 5 6 7 8 9 10 11 Please note The...

Page 8: ...g clip bearing Installation with universal bearing Push the motor with the square into the opening of the bearing and secure with cotter pin Installation with cover cap bearing Remove screws from meta...

Page 9: ...er fig 4 7 4 8 5 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at this point 2 mounting options Universal bearing and cover cap bearing 3...

Page 10: ...cupied and must be insulated To do this push the enclosed wire end cap onto the wire end and press it together with crimping pliers or combination pliers Wire end cap 3T MOTORS Tubular motors Installa...

Page 11: ...g the end points with adjustment cable ESK Connect tubular motor to ESK Test the direction of rotation of the motor and change it if necessary To change the direction of rotation swap the up and down...

Page 12: ...SW40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Explanation Avoid overstressing and resulting premature aging of the motor by using the...

Page 13: ...e support tube fig 3 4 Remove the crank mechanism fig 3 5 Attention Awning arms are under strong tension 2 1 Limit switch adapter Motor head 2 2 2 3 Securing bracket 2 4 Click Shaft adapter Remove the...

Page 14: ...connection diagram of time switches differs from this circuit diagram Please refer to the corresponding manual for the connection diagram If the end points are set using the ESK do not connect the sw...

Page 15: ...eturn step by step Setting the end points with adjustment cable ESK Connect tubular motor to ESK Test direction of rotation Press Up button Awning moves IN Press Down button Awning moves OUT Change th...

Page 16: ...ler shutter motor page 11 awning motor page 15 the motor stops running after continuous operation The thermal protection switch of the motor has tripped After a cooling phase min 10 min the motor is r...

Page 17: ...nden Anforderungen der aufgef hrten EG EU Richtlinien erf llt 2014 35 EU Niederspannungsrichtlinie 2014 30 EU EMV Richtlinie 2011 65 EU RoHS Richtlinie 2012 19 EU WEEE Richtlinie angewandte Standards...

Page 18: ...3 5 mm Limit switch adapter Shaft adapter 3 8 m m Engine bearing Roll off bearing Enables the rolling shutter to unroll in case of defective motor or power failure Motor bearing for tubular motors wit...

Page 19: ...140 cm 160 cm Suspension spring Maxi Required when using roller shutter motors Maxi spring up to 65 mm profile height For roller shutter shaft SW60 Powder coated Anti burglary effect Pick up width 10...

Page 20: ...www instagram com 3tcomponents twitter com 3TComponents INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS Service and Quality make the difference 3T Components GmbH Co KG Bahnhofstr 34 55578 Walle...

Reviews: