10
Shutter motor
230 V / 50 Hz
Power grid
230 V / 50 Hz
1) white = Programming cable, not assigned
2) black = Departure or ascent
3) brown = Departure or ascent
4) blue = N Neutral conductor
5) green/yellow = PE Protective conductor
1) brown / black = L1 / Phase
2) blue = N Neutral conductor
3) green/yellow = PE Protective conductor
1 (L1)
2 (N)
3 (PE)
2 (Up/Down)
3 (Up/Down)
4 (N)
5 (PE)
1
The connection diagram of time switches differs from this
circuit diagram! Please refer to the corresponding manual
for the connection diagram.
If the end points are set using the ESK setting cable, do not
connect the switch or timer until after the end points have
been set (page 11)!
2 (Up/Down)
3 (Up/Down)
4 (N)
5 (PE)
1
Adjustment cable ESK
Shutter motor
230 V / 50 Hz
The white wire is unoccupied and
must be insulated. To do this, push
the enclosed wire end cap onto the
wire end and press it together with
crimping pliers or combination pliers.
Wire end cap
3T-MOTORS Tubular motors
| Installation instructions
INSTALLATION INSTRUCTIONS
•
On the opposite side of the motor, push the roller capsule out of the roller shutter shaft until it fits into the ball bearing inserted in the wall bearing.
•
Fix roller capsule to roller shutter shaft with self-tapping screw. Position the screw at a punched hole. This prevents the screw from slipping.
7
Shutter motor wiring:
•
Connect the roller shutter motor and switch (or timer) to the mains.
•
The electrical connection of the roller shutter motor and control unit may only be carried out by qualified personnel.
•
If the drive should run in the opposite direction after installation, the motor’s upstream and downstream leads (brown + black) must be turned.
Roller capsule
Wall b
Ball bearing