4.7 TRIOS Scanner, TRIOS Scanner Tip and TRIOS 
Protection Tip Description

TRIOS system consists of:

TRIOS Scanner (L1-2): 

Wireless handheld dental intraoral scanner for 
scanning a patient.  
Two main areas of the TRIOS scanner are referred  
to in this guide: mirror housing and scanner body.

TRIOS Scanner tip (TST-11): 

Re-usable TRIOS scanner tip attached to the TRIOS 
scanner. A tip is needed for the scanner to be able 
to scan.

TRIOS Sleeve (TSL-01): 

Single use sleeve to cover the TRIOS scanner.

TRIOS Protection Tip (TST-13): 

Protects the optical window of the TRIOS scanner 
from damage and dirt when the TRIOS scanner  
is not in use. Enables the scanner to run self-test, 
when mounted.

Please follow the steps below for attaching and detaching the scanner tip and protection tip: 

1. To attach the tip, place the tip over the mirror 

housing facing downwards until it clicks. 

2. To detach the tip, pull the tip away from  

the mirror housing.

The TRIOS scanner has built-in tip detection.

A set of TRIOS scanner tips are delivered with the TRIOS scanner.  
The TRIOS scanner tip is the only applied part.

IMPORTANT NOTICE 

The TRIOS scanner tips can only be mounted one way

4.8 Battery and Battery Charger Description

A set of batteries for the TRIOS scanner (TB-04): 

Batteries for the TRIOS scanner with LED light  
to indicate battery status.

Be aware that the batteries must be stored and 
operated under correct conditions, see section 4.13.

A battery charger (C2BP): 

With two ports to charge TB-04 batteries.

Be aware that the battery charger must be stored 
and operated under correct conditions,  
see section 4.13.

Power (mains) cable and plug:

 

 

The charger has a detachable cable (C8 connector) appropriate for your location, supplied  
in the packaging. 

4.9 Other System Elements Description

Pod (LP1-2): 

Holder for the scanner.

A USB wireless dongle for the PC.

A USB license dongle.

For L1P-1F systems: 
TRIOS Patient Monitoring (TPM) Software:

Software for aid in diagnostics of caries.

4.10 Setting up TRIOS

It is recommended that unpacking, assembly and connection of the TRIOS System be performed 
by TRIOS authorized technical service personnel. 

It is recommended to fully charge batteries for the TRIOS scanner before use.

CAUTION

Let the system adjust to room temperature before use.

WARNING

Examine all parts of the system. Look for physical damage, loose parts 
or signs of wear that could interfere with proper use and functionality. 
Contact your service provider if there is visible damage or malfunctioning.

Charging batteries:

Before you start: 

Place the battery charger on a flat surface horizontally.

Step 1:

 Attach the power cord to the charger and plug it into mains power.

Step 2:

 Push the batteries one by one into the charger until they click into place.  

When charging, the 5 LEDs on the end of the battery will indicate the status:

Each LED represents 20% of the battery capacity. 

Five constant LEDs means that the charging  
is complete.

While charging is ongoing each LED will light up one 
at a time. The battery status will then be shown, with 
each LED representing 20% battery capacity. 

If any other charging pattern appears, a charging 
error has occurred. In this case, remove the 
batteries from the charger and reinsert them. 
If charging errors continue, please contact 3Shape 
support ([email protected]). 

There is an LED under the battery charger. The LED has the following indications: 

A green light indicates the battery charger is on  
and working

A blue light indicates the power is unstable.  
Unplug and reinsert the power for the charger.  
If the LED continues to indicate a blue light  
please contact support ([email protected]). 

A white light indicates the battery may have been 
inserted incorrectly. Try to insert the battery again.  

If the LED continues to indicate a white light,  
please contact support ([email protected]).

Please follow the steps below for assembling the TRIOS system:

Before you start:

 Place the pod on a flat and horizontal surface optimally in relation  

to the patient chair and your work position. Attach the TRIOS protection tip to the 
TRIOS scanner if not already in place. 

Step 1:

 Insert a fully charged battery into the rear  

of the TRIOS scanner. 

Step 2: 

Place the TRIOS scanner in the pod.

Step 3:

 Clean and sterilize a TRIOS scanner tip prior to first time usage.  

See section 7 for cleaning and sterilization instructions.

Summary of Contents for L1P-1

Page 1: ...APR 2022 3Shape TRIOS 5 Safety and Setup Guide L1P 1 L1P 1F...

Page 2: ...system please carefully read and follow the instructions in this safety and setup guide and in the online helpsystem Pleasealwayskeepthissafetyandsetupguidenearthesystem Please follow all safety infor...

Page 3: ...safety requirements for medical electrical equipment by combining it with other equipment is responsible for conducting appropriate inspection and testing to ensure continued safe use of the equipment...

Page 4: ...Systembe performed byTRIOSauthorizedtechnicalservicepersonnel It is recommended to fully charge batteries for the TRIOS scanner before use CAUTION Let the system adjust to room temperature before use...

Page 5: ...midity 10 85 non condensing Atmospheric pressure 800 1100 hPa Transport Conditions Ambient temperature range 10 50 C 14 122 F Relative humidity 10 85 Non condensing Atmospheric pressure 620 1200 hPa 4...

Page 6: ...e b V1 3 Vrms V2 6 Vrms Note b Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 7 GHz E1 3 V m 80 MHz to 2 7 GHz Electromagnetic environment guidelines Portable and mobile RF communications equipment shoul...

Page 7: ...Connection The wireless TRIOS scanner is intended to be used indoors in a domestic or commercial electromagnetic environment The wireless connection is intended to relay image stream dataandcontrolda...

Page 8: ...ion in visual acuity and afterimages leading to irritation annoyance visual impairment and even accidents depending on the situation 5 6 Hygiene Forinstructionsonhowtomountthesingle usesleeveseetheTRI...

Page 9: ...nner during patient examination WARNING The TRIOS Sleeve must only be used once to avoid cross contamination 7 Cleaning Disinfection and Sterilization The following TRIOS system items shall be cleaned...

Page 10: ...ants Dispose of the CaviWipe Step 3 Remove gross contaminants from metal holder Take a CaviWipe Wipe the surface of the metal holder to remove any gross contaminants Dispose of the CaviWipe Step 4 Dis...

Page 11: ...TRIOS scanner window follow these steps for optimal scan quality Step 1 Take a damp non woven swab and gently rub it on the inside and outside of the TRIOS scanner tip window as well as on the window...

Page 12: ...10030138A April 2022 Copyright 3Shape TRIOS A S More information at 3Shape com Let s change dentistry together 3Shape TRIOS A S Holmens Kanal 7 1060 Copenhagen Denmark...

Reviews: