User Manual
3onedata proprietary and confidential 66
Copyright © 3onedata Co., Ltd.
1. Log in to the Web configuration interface and select “Serial Server> COM Mode
Settings”.
2. Select “COM1” in the “Port” drop-down list.
3. Click the "Work Mode" drop-down list box and select "TCP Server Mode".
4. Click the "Session Number" drop-down list box and select "1".
5. Enter "30000" in the "Local Port" text box.
6. Other parameters remain the default, click “submit”.
Step 4
Run the "DebugTool” software, for the host to create TCP client.
1. To install and run "DebugTool” Software, click “Create Connection” drop-down list
box and choose “Create Network Debugging> TcpClient”.
2. In the "Local IP" drop-down list box, select the IP address "192.168.1.61" of the
host PC (that is, the TCP client).
3. In the "Device IP" text box, enter the IP address "192.168.1.250" of the serial server