User Manual
3onedata proprietary and confidential 93
Copyright © 3onedata Co., Ltd.
2. Select “COM1” in the “Port” drop-down list.
3. Set the “BaudRate”, “DataBits”, “StopBits” and “ParityBits” in the “Settings” option
box.
4. Other parameters remain the default, click “Submit”.
Setp 3
Configure the working mode of the serial server.
1. Log in to the Web configuration interface and select “Serial Server> COM Mode
Settings”.
2. Select “COM1” in the “Port” drop-down list.
3. Click the “Work Mode” drop-down list box and select “UDP Multicast Mode”.
4. Click the “Session Number” drop-down list box and select “1”.
5. Click the “Group Number” drop-down list box and select “1”.
6. Enter the group address "224.0.0.0" of the host PC in the "Dest Address" text box.
7. Enter the local port number "31000" of the host PC in the "Dest Port" text box.
8. Enter the group address "239.0.0.0" of the host PC in the "Group Address/ Group
1" text box.
9. Enter the local port unmber "30000" of the serial server in the "Listen port" text box.