3onedata IPS7112G-4GS-8POE User Manual Download Page 5

- 5 - 

DC support redundant power supply 

Consumption 

No-load consumption: 7.30W@48VDC 
Full-load consumption (PoE): 103.49W@48VDC 

Working environment 

Working temperature: -40

70

 

Storage temperature: -40

85

 

Relative Humidity: 5%~95 %( no condensation) 

Mechanical Structure 

Shell: IP40 protect grade, metal shell 
Installation: DIN-Rail mounting 
Weight: 1.07kg 
Size (W×H×D): 70mm×160mm×130mm 

Industry Standard 

EMI: FCC Part 15, CISPR (EN55022) class A   
EMS: EN61000-4-2 (ESD), Level 3 

EN61000-4-4 (EFT), Level 3 

Shock: IEC 60068-2-27 
Free fall: IEC 60068-2-32 
Vibration: IEC 60068-2-6   

Certification 

CE, FCC, RoHS, UL508 (Pending) 

Warranty: 

5 years

 

 

Summary of Contents for IPS7112G-4GS-8POE

Page 1: ...working temperature can meet all kinds of industrial environment requirement and provide the solution of the economy Packing list The industrial PoE switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial PoE switch ⅹ 1 User manual ⅹ 1 Documentation and software CD ⅹ 1 DIN Rail mounting ki...

Page 2: ...f the device Between the two terminal relay as an open circuit state in normal non alarm state when there is power alarm information to the closed state The two terminal block connector are used to detect power failure and network anomaly The two wires attached to the Fault contacts form a closed circuit when the device port connection disconnect or has lost power supply from one of the DC power i...

Page 3: ... make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B shown as below or A1 to A2 and B1 to B2 LED Indicator LED indictor light on the front panel of product the function of each LED is described in the table as below System indication LED LED State Description P 1 2 ON Power is being supplied to power input PWR input OFF Power is not being s...

Page 4: ...ing should be moderate not too tight and should be separated from other cables 8 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard IEEE802 3 IEEE802 3u IEEE802 3z ab IEEE802 3af at IEEE802 3x IEEE802 1Q IEEE802 1p IEEE802 1W D IEEE802 1s IEEE802 3ad IEEE802 1X Protocol ARP ICMP TCP DHCP DNS HTTP Telnet SW Ring RSTP MSTP LLDP SSH...

Page 5: ...ive Humidity 5 95 no condensation Mechanical Structure Shell IP40 protect grade metal shell Installation DIN Rail mounting Weight 1 07kg Size W H D 70mm 160mm 130mm Industry Standard EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 4 EFT Level 3 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Vibration IEC 60068 2 6 Certification CE FCC RoHS UL508 Pending Warranty 5 years ...