background image

tighten it with M4 screws to the marked position. 

Mounting ends. 

 

Disassembling Device

 

Step 1 

Device power off. 

Step 2 

Hold the equipment steady and unscrew the screw 
on the wall 

Step 3 

Take out the device, disassembling ends. 

Note before powering on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above. 

Power Supply Connection

 

 

12~48VDC power supply 

Model I provides 3-pin 5.08mm pitch industrial 

terminal blocks, in which V+ and V- are DC input. 
FG is the shell or grounding. The power supply 
supports non-polarity connection, and the 
equipment can still work normally after reverse 
connection. Voltage range: 12~48VDC. 

 

100~240VAC Power Supply   

Model II provides 3-Pin 5.08mm pitch industrial 
terminal blocks, in which L/+ and N/- are AC input. 
FG is the shell or grounding. Supports 220 VAC 
power supply input. Voltage range: 100~240VAC. 

DIP Switch Settings

 

The device provides 4 pins DIP switch for 
function setting, in which “ON” is the enabled end. 
DIP switch definition and operation method are 

as follows: 

DIP  Definition 

Operation 

Master/slave device 

Set the DIP Switch to 
“ON” and the device 
works as the master 
device of the ring network; 
Cancel setting of DIP 
Switch to “ON” , device 
works as ring network 
slave device. 

Reserved 

 

Reserved 

 

Reserved 

 

Notes: 

 

The serial port fiber MODEM should be used in pairs, 
and the serial port number on the two devices should be 
one-to-one correspondence. 

 

If the device passes through the fiber interface group 
ring, the ring network main station shall be enabled by 
the DIP switch, that is, one master device and one slave 
device. 

Serial Port Connection

 

 

RS-485 serial port 

The RS-485 serial port provided by the 
products of this series is 5-pin 3.81mm pitch 
industrial terminal blocks. The pin definitions 

are shown in the table below: 

PIN 

RS-485 

D+(A) 

D-(B) 

GND 

— 

— 

Checking LED Indicator

 

The device provides LED indicators to monitor the device 

working status with a comprehensive simplified 
troubleshooting; the function of each LED is described in the 
table as below: 

LED 

Indicate 

Description 

RUN 

Blinking 

System runs normally 

OFF 

The system is not running or 
running abnormally 

M/S 

ON 

The device works as the 
master device of the ring 
network 

OFF 

The device works as the slave 
device of the ring network 

LINK (1-2) 

ON 

Fiber port has established valid 
network connection 

OFF 

Fiber port hasn’t established 
valid network connection 

COM(1-4) 

Blinking 

Serial port is transmitting and 

receiving data normally. 

OFF 

Serial port is transmitting data 

or receiving data abnormally 

Specification

 

Panel 

 

Fiber port

 

SC/ST/FC optional, support ring 
network redundancy

 

Serial Port

 

RS-485 serial port, 5-pin 5.08mm 
pitch terminal blocks

 

Console port 

Reserved 

Indicator 

Running status indicator, 
master/slave device status 
indicator, copper port connection 
status indicator, serial port 
indicator

 

Power Supply

 

 

Reviews: