24
4.3
Power-on Utilities
There are six power-on utilities to set up and test printer hardware. These utilities are activated by
pressing the FEED button then turning on the printer power simultaneously and releasing the button
with an assorted color of LED.
Please follow the steps below for different power-on utilities.
1.
Turn off the printer power switch.
2.
While holding the button down, turn on the power switch.
3.
Release the button when the LED changes color. Each color indicates a different function.
Power on utilities
The LED color will be changed as following pattern:
LED color
Functions
Purple
Red
(5 blinks)
Purple
(5 blinks)
Bule
(5 blinks)
Bule/Purple
(5 blinks)
Red/Purple
(5 blinks)
Solid bule
1. Ribbon sensor calibration and gap /
black mark sensor calibration
Release
2. Gap / black mark sensor calibration,
Self-test and enter dump mode
Release
3. Printer initialization
Release
4. Set black mark sensor as media sensor
and calibrate the black mark
sensor
Release
5. Set gap sensor as media sensor and
calibrate the gap sensor
Release
6. Skip AUTO.BAS
Release