6.4 Setting Up the Unit with the Product Guide
Before you can work with the unit, it must be set up for the corresponding product .
Figure 17
1 . Loosen the three bolts (Figure 17B) M8x20 DIN EN ISO 4762, Allen key size 6, at the back of the
mounting bracket .
2 . Move the mounting bracket to the desired position . The attached scale (Figure 17A) serves as an
adjustment aid for the distance between the product stop and the center of the bonding track .
3 . Tighten the three bolts (Figure 17B) M8x20 DIN EN ISO 4762, Allen key size 6, at the back of the
mounting bracket . The track center is set up .
Figure 18
4 . Hold the base plate of the bonding head firmly using the handle bar (Figure 18C) and release the
locking lever (Figure 18B) .
5 . Move the base plate to the desired position using the handle bar (Figure 18C) . The attached scale
(Figure 18A) serves as an adjustment aid for the height of the product .
6 . Tighten the locking lever (Figure 18B) again . The application height is set up .
7 . Adjust the correct track position .
NOTE:
To set up the track position in the unit please see chapter
6.6 Setting the
Track Position
.
A
B
B
A
C