background image

3M

 

Water Filtration Products

Table of Contents

Safety Information .......................................................................................................................................2
Warning Statements ....................................................................................................................................2
Caution/Important Notes ..............................................................................................................................3
SF1XX Manifold and ScaleGARD HT Systems ...............................................................................................3
Inlet and Outlet Connections ........................................................................................................................3 

Product Dimensions .....................................................................................................................................4 
How to Use The “Inlet/Outlet” Fitting Retention Clips ....................................................................................4
Equipment Installation .................................................................................................................................5
Equipment Start-up Procedure  ....................................................................................................................6
Cartridge Change-out Procedure ..................................................................................................................6
Troubleshooting ...........................................................................................................................................6 
Replacement Parts Listing ...........................................................................................................................7
Warranty ......................................................................................................................................................8

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation.  Retain 
these instructions for future reference.

Intended Use:

 

The manifold and water filtration systems are intended for use in filtering potable water in the foodservice industry 
and have not been evaluated for other uses. These systems are installed at the point of use and must be installed as 
specified in the installation instructions. 

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or seri-
ous injury and/or property damage.

CAUTION

       

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moder-
ate injury and/or property damage.

CAUTION

Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking:
 

  • 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with the ingestion of contaminants:
 

• 

Do not 

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

      before or after the system.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric 
wiring or water pipes in the area of installation:

  • 

Do not

 install near electric wiring or piping which may be in path of a drilling tool when selecting the  

      position to mount the filter bracket.

To reduce the risk of physical injury:

  • Depressurize system as shown in manual prior to cartridge removal.

To reduce the risk associated with back strain:

  • Follow safe lifting procedures.

2

Summary of Contents for SF1 Series

Page 1: ...Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems 3MTM Water Filtration Products Installer Please leave this manual with owner operator ...

Page 2: ... if not avoided could result in death or seri ous injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moder ate injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with choking Do not allow children under 3 ...

Page 3: ... C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552 kPa you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure Do not install where water hammer conditions m...

Page 4: ...mi circular in shape with three internal tabs bottom center and top Tab interlaces with windows in the manifold head near each connection port Clip is flexible and easily assembled following these instruction and illustrations 1 Insert fitting into manifold 2 With fitting inserted into manifold port snap clip into place beginning at the bottom window 3 Push center tab into center window 4 Finally ...

Page 5: ...ts 3 Select fasteners not included and tools appropriate for the installation location wall support structure mount ed to wall studs concrete etc CAUTION To reduce the risk associated with property damage due to water leakage Ensure that the location and fasteners will support the weight of the system Approx 10 5 lbs 4 8 kg when installed and full of water 4 Mount the manifold filter system to a w...

Page 6: ...osition 2 Depressurize system 3 Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left 4 Using both hands and holding cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down IMPORTANT NOTE A small amount of water will drain from manifold as cartridge is re moved 5 Remove sanitary cap from new cartridge Ins...

Page 7: ... 1 Scale inhibitor addition 4 85005 49 Pressure gauge 1 Monitor outlet water pressure 5 85 8528 Clip 1 Retain inlet outlet fittings 6 63597320 O ring 1 Seal inlet outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225007 Outlet fitting kit right front 1 Outlet to equipment 9 60 235380 3 4 x 3 4 ball valve 1 Inlet water shut off 10 Inquire Retainer Kit 1 Secure...

Page 8: ...ragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty questions please call 866 990 9785 or mail your request to Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 Proof of purchase original sales rec...

Reviews: