Equipment Start-up Procedure

1.   Turn on incoming water to system.
2.   Pressurize system by rotating the inlet ball valve handle 1/4 turn counter-clockwise to the “ON” position.
3.   Check for leaks.
4.   Use any downstream vent to remove trapped air. 
5.   Flush system in accordance with the Performance Data Sheet for the water filter cartridge.  System is now 

ready to use.

Cartridge Change-out Procedure

CAUTION

To reduce the risk associated with property damage due to water leakage:

  • Read and follow 

Use Instructions before installation and use of this system.

  • Installation and Use 

MUST

 comply with all state and local plumbing codes.

  • The disposable filter cartridge 

MUST

 be replaced every 12 months or at the rated capacity or if a noticeable 

reduction in flow rate occurs.

The water filter cartridge will need to be changed every 6-12 months or when low pressure is indicated on the 
manifold’s pressure gauge, whichever occurs first. Depending on local water quality, you may need to change the 
cartridges prior to the recommended change-out.

1.  Shut off the inlet water by rotating the inlet ball valve 1/4 turn clockwise to the “OFF” position.
2  Depressurize system.
3.  Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left.
4.  Using both hands and holding cartridge from the bottom, rotate the cartridge a quarter turn to the left and 

gently pull down. IMPORTANT NOTE: A small amount of water will drain from manifold as cartridge is re-
moved.

5.  Remove sanitary cap from new cartridge. Install cartridge with a quarter turn to the right until cartridge comes 

to a complete stop. 

6.  Remove the small scale inhibitor cartridge by rotating to the left (counterclockwise) until the threads are dis

-

engaged.  Replace with a new cartridge by rotating to the right (clockwise) until the threads are fully engaged 

and snug, regardless of final label orientation. 

7.   Slowly turn the inlet ball valve on the manifold 1/4 counter-clockwise to the “ON” position and check for 

leaks.

8.  Flush system in accordance with the Performance Data Sheet. System is now ready for use.

6

No water flow through system

Inlet valve closed

Filter clogged

Check shut-off valve position

Replace cartridge

Not enough water to the 

downstream application(s)

Low incoming water pressure

Filter clogged

Check source

Replace cartridge

Short filter life

Temporarily dirty water

Change cartridge or install an 
additional upstream pre-filter.

Troubleshooting

Summary of Contents for SF1 Series

Page 1: ...Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems 3MTM Water Filtration Products Installer Please leave this manual with owner operator ...

Page 2: ... if not avoided could result in death or seri ous injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moder ate injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with choking Do not allow children under 3 ...

Page 3: ... C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552 kPa you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure Do not install where water hammer conditions m...

Page 4: ...mi circular in shape with three internal tabs bottom center and top Tab interlaces with windows in the manifold head near each connection port Clip is flexible and easily assembled following these instruction and illustrations 1 Insert fitting into manifold 2 With fitting inserted into manifold port snap clip into place beginning at the bottom window 3 Push center tab into center window 4 Finally ...

Page 5: ...ts 3 Select fasteners not included and tools appropriate for the installation location wall support structure mount ed to wall studs concrete etc CAUTION To reduce the risk associated with property damage due to water leakage Ensure that the location and fasteners will support the weight of the system Approx 10 5 lbs 4 8 kg when installed and full of water 4 Mount the manifold filter system to a w...

Page 6: ...osition 2 Depressurize system 3 Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left 4 Using both hands and holding cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down IMPORTANT NOTE A small amount of water will drain from manifold as cartridge is re moved 5 Remove sanitary cap from new cartridge Ins...

Page 7: ... 1 Scale inhibitor addition 4 85005 49 Pressure gauge 1 Monitor outlet water pressure 5 85 8528 Clip 1 Retain inlet outlet fittings 6 63597320 O ring 1 Seal inlet outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225007 Outlet fitting kit right front 1 Outlet to equipment 9 60 235380 3 4 x 3 4 ball valve 1 Inlet water shut off 10 Inquire Retainer Kit 1 Secure...

Page 8: ...ragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty questions please call 866 990 9785 or mail your request to Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 Proof of purchase original sales rec...

Reviews: