background image

Equipment Installation

CAUTION

To reduce the risk associated with property damage due to water leakage:

  • 

Do not

 use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic 

       plumbing.

  • On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape 

only

, pipe dope properties may 

       deteriorate plastic.

  • Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtight-

 

 ening occurs.

  • 

Do not

 install near water pipes which will be in path of a drilling tool when selecting the position to mount  

 the bracket

  • Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.
  • Ensure that the location and fasteners will support the weight of the system when installed.
  • Ensure all tubing and fittings are secure and free of leaks.

IMPORTANT NOTES

 

• Failure to follow instructions may void warranty.

  • Allow a minimum of 3” (7.6 cm) clear space under filter to facilitate cartridge change.
  • Install with the inlet and outlet ports as labeled.  Make sure not to reverse connections.
  • Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line.

The SF1XX manifold may be used with metal or non-metallic piping systems.

CAUTION

To reduce the risk associated with property damage due to water leakage:

  • Any non-metallic fittings used in the installations must be of adequate rating for the line pressure.

1.  Shut off incoming cold water supply.

2.  Select the installation location.  IMPORTANT NOTE: Allow a minimum of 3 in (7.6 cm) of space below the car

-

tridge for change-outs. 

3.  Select fasteners (not included) and tools appropriate for the installation location (wall, support structure mount

-

ed to wall studs, concrete, etc.).   

CAUTION

To reduce the risk associated with property damage due to water leakage:

  • Ensure that the location and fasteners will support the weight of the system (Approx. 10.5 lbs [4.8 kg])

 

when installed and full of water.

4.  Mount the manifold/filter system to a wall using the mounting holes provided on the back plate of the metal 

bracket.  

• It is recommended to first draw a level line on the mounting surface at the height of the fasteners. 
• Mark the location of the fasteners using the bracket as a template or by measuring the distance between 

 

the mounting holes.

• Install the fasteners and allow 1/4”-3/8” (6-10 mm) of each fastener to protrude from the surface. 
• Install the manifold onto the fasteners.
• Tighten the fasteners.

5.  Install inlet (left rear) and outlet fittings (right front). All connections terminate with a ¾” NPT (male) fitting.  The 

inlet kit includes the fitting and a ball valve. The kit for the right front side outlet includes the fitting, a stainless-
steel tee, a nipple, a check valve and another nipple.  Refer to section “How to Use the Inlet/Outlet Fitting 

Retention Clips” are on page 4. (PTFE tape is not included).  

6.  Remove the sanitary caps from the cartridge, and apply a light coat of water or food-grade lubricant to the o-

rings on each of the cartridges.  

7.  Align the tabs of the water filter cartridge with the slots in the retaining plate and insert the cartridge into the 

manifold.

8.  Turn the cartridge to the right until a clicking sound is heard; the clicking sound indicates the cartridge is prop

-

erly engaged.

9.  Install the scale-inhibitor cartridge by engaging the threads in the stainless steel tee and turning to the right 

(clockwise) until snug, regardless of the final label orientation.

5  

Summary of Contents for SF1 Series

Page 1: ...Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems 3MTM Water Filtration Products Installer Please leave this manual with owner operator ...

Page 2: ... if not avoided could result in death or seri ous injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moder ate injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with choking Do not allow children under 3 ...

Page 3: ... C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552 kPa you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure Do not install where water hammer conditions m...

Page 4: ...mi circular in shape with three internal tabs bottom center and top Tab interlaces with windows in the manifold head near each connection port Clip is flexible and easily assembled following these instruction and illustrations 1 Insert fitting into manifold 2 With fitting inserted into manifold port snap clip into place beginning at the bottom window 3 Push center tab into center window 4 Finally ...

Page 5: ...ts 3 Select fasteners not included and tools appropriate for the installation location wall support structure mount ed to wall studs concrete etc CAUTION To reduce the risk associated with property damage due to water leakage Ensure that the location and fasteners will support the weight of the system Approx 10 5 lbs 4 8 kg when installed and full of water 4 Mount the manifold filter system to a w...

Page 6: ...osition 2 Depressurize system 3 Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left 4 Using both hands and holding cartridge from the bottom rotate the cartridge a quarter turn to the left and gently pull down IMPORTANT NOTE A small amount of water will drain from manifold as cartridge is re moved 5 Remove sanitary cap from new cartridge Ins...

Page 7: ... 1 Scale inhibitor addition 4 85005 49 Pressure gauge 1 Monitor outlet water pressure 5 85 8528 Clip 1 Retain inlet outlet fittings 6 63597320 O ring 1 Seal inlet outlet fittings 7 6225005 Inlet fitting kit left rear 1 Inlet fitting with ball valve 8 6225007 Outlet fitting kit right front 1 Outlet to equipment 9 60 235380 3 4 x 3 4 ball valve 1 Inlet water shut off 10 Inquire Retainer Kit 1 Secure...

Page 8: ...ragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or country to country For any warranty questions please call 866 990 9785 or mail your request to Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 Proof of purchase original sales rec...