Changing To Another 3M™ Adhesive Requiring A
Different Temperature Module
Caution
Use only the proper temperature
module for the 3M Quadrack
adhesive used. Failure to do so
may cause burns or damage
applicator.
Refer to Table 1 in the
Temperature Module Installation
section for proper module selection
for 3M Quadrack adhesive used.
Make sure the proper temperature module is in the applicator for the
adhesive then in the entry track. Refer to Table 1 on page 4 or the chart
on pages 29-30 (Temperature Module Selections section) for selection of
the proper temperature module to be used with your
3M™ Quadrack™ adhesive.
1. Extrude the remaining adhesive from the entry track.
2. Turn the applicator off by pressing the rocker switch at the rear of
the handle (see Figure K). The red visor on the rocker switch
disappears, indicating the applicator is off.
3. Unplug the applicator and allow it to cool to room temperature.
4. Remove the temperature module by simultaneously unscrewing the
fastener and lifting the module out (see Figure L). Save the module
for possible reuse.
Note:
Do not unscrew the fastener more than 8 turns before lifting
the module out.
Caution
Allow applicator to cool to room
temperature before servicing.
Failure to do so
may cause burns.
!
!
Ho
tM
elt
Ap
plic
ato
rE
C
3
Sc
otc
h-W
eld
™
Figure K
Figure L
© 3M 2006