3M Protecta User Instruction Manual Download Page 7

7

1.0  PRODUCT APPLICATION

1.1 PURPOSE: 

Anchorage Connectors are designed to provide anchorage connection points for Fall Arrest

1

 or Fall Restraint

2

 

systems: Restraint, Work Positioning, Personnel Riding, Rescue, etc.

 

;

Fall Protection Only:

 This Anchorage Connector is for connection of Fall Protection Equipment. Do not connect 

Lifting Equipment to this Anchorage Connector.

1.2 

STANDARDS:

 Your Anchorage Connector conforms to the national or regional standard(s) identified on the front cover 

of these instructions. If this product is resold outside the original country of destination, the re-seller must provide these 

instructions in the language of the country in which the product will be used.

1.3 SUPERVISION:

 Use of this equipment must be supervised by a Competent Person

3

.

1.4 TRAINING:

 This equipment must be installed and used by persons trained in its correct application. This manual is to be 

used as part of an employee training program as required by CE. It is the responsibility of the users and installers of this 

equipment to ensure they are familiar with these instructions, trained in the correct care and use of this equipment, and 

are aware of the operating characteristics, application limitations, and consequences of improper use of this equipment.

1.5 

RESCUE PLAN:

 When using this equipment and connecting subsystem(s), the employer must have a rescue plan and 

the means at hand to implement and communicate that plan to users, authorized persons

4

, and rescuers

5

. A trained, on-

site rescue team is recommended. Team members should be provided with the equipment and techniques to perform a 

successful rescue. Training should be provided on a periodic basis to ensure rescuer proficiency.

1.6 

INSPECTION FREQUENCY:

 The Anchorage Connector shall be inspected by the user before each use and, additionally, 

by a competent person other than the user at intervals of no longer than one year.

6

 Inspection procedures are described in 

the 

“Inspection and Maintenance Log”

. Results of each Competent Person inspection should be recorded on copies of the 

“Inspection and Maintenance Log”

.

1.7 

AFTER A FALL:

 If the Anchorage Connector is subjected to the forces of arresting a fall, it must be removed from service 

immediately, clearly marked “DO NOT USE”, and then destroyed.

2.0  SYSTEM REQUIREMENTS

2.1 ANCHORAGE:

 Anchorage requirements vary with the fall protection application. Structure on which the 

Anchorage Connector is placed or mounted must meet the Anchorage specifications defined in Table 1.

2.2 

PERSONAL FALL ARREST SYSTEM:

 Figure 1 illustrates the application of this Anchorage Connector. Personal Fall Arrest 

Systems (PFAS) used with the system must meet applicable Fall Protection standards, codes, and requirements. The PFAS 

must incorporate a Full Body Harness, and limit Arresting Force to the following values:

Maximum Arresting Force

Free Fall

PFAS with Shock Absorbing Lanyard

6 kN (1,350 lb)

Refer to the instruction(s) included with your 

Lanyard or SRD for Free Fall limitations.

PFAS with Self Retracting Device (SRD)

6 kN (1,350 lb)

2.3 

FALL PATH AND SRD LOCKING SPEED:

  A clear path is required to assure positive locking of an SRD. Situations 

which do not allow for an unobstructed fall path should be avoided. Working in confined or cramped spaces may not allow 

the body to reach sufficient speed to cause the SRD to lock if a fall occurs. Working on slowly shifting material, such as 

sand or grain, may not allow enough speed buildup to cause the SRD to lock.

2.4 HAZARDS:

 Use of this equipment in areas with environmental hazards may require additional precautions to prevent 

injury to the user or damage to the equipment. Hazards may include, but are not limited to: heat, chemicals, corrosive 

environments, high voltage power lines, explosive or toxic gases, moving machinery, sharp edges, or overhead materials 

that may fall and contact the user or Personal Fall Arrest System.

2.5 

FALL CLEARANCE:

  Figure 3 illustrates the components of a Fall Arrest. There must be sufficient Fall Clearance (FC) 

to arrest a fall before the user strikes the ground or other obstruction. Clearance is affected by a number of factors 

including: Anchorage Location, (A) Lanyard Length, (B) Lanyard Deceleration Distance or SRD Maximum Arrest Distance, 

(C) Harness Stretch and D-Ring/Connector Length and Settling. Refer to the instructions included with your Fall Arrest 

subsystem for specifics regarding Fall Clearance calculation.

2.6 

SWING FALLS:

 

 

Swing Falls occur when the anchorage point is not directly above the point where a fall occurs (see Figure 

4). The force of striking an object in a swing fall may cause serious injury or death. Minimize swing falls by working as directly 

below the anchorage point as possible. Do not permit a swing fall if injury could occur. Swing falls will significantly increase the 

clearance required when a Self-Retracting Device or other variable length connecting subsystem is used.

1  Fall Arrest System:

 A collection of Fall Protection Equipment configured to arrest a free fall.

2  Fall Restraint System:

 A collection of Fall Protection Equipment configured to prevent the person’s center of gravity from reaching a fall hazard.

3  Competent Person:

 One who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, 

hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.

4  Authorized Person:

 For purposes of the Z359 standards, a person assigned by the employer to perform duties at a location where the person will be exposed 

to a fall hazard.

5 Rescuer:

 Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

6  Inspection Frequency:

 Extreme working conditions (harsh environments, prolonged use, etc.) may require increasing the frequency of competent person 

inspections.

Summary of Contents for Protecta

Page 1: ...CE Product Quality Control No 0086 BSI Kitemark Court Davy Avenue Knowlhill Milton Keynes MK5 8PP United Kingdom 1 A B C 2104704 48 9cm x 5 3cm x 9 9cm 19 3in x 2 1in x 3 9in 1 7 kg 3 6 lbs 8 9 cm 35...

Page 2: ...2 2 2104704 B A C D E E C D 3 4 C B A FC B C FC 5 6 A B C D E F G A B C...

Page 3: ...3 7 A B C D 8 1 2 3 9 A B...

Page 4: ...4 10 A B A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17b 17a 19 18a 18b...

Page 5: ...y the drill or the device Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards incl...

Page 6: ...s System Specifications Capacity 1 Person with a combined weight clothing tools etc of no more than 140 kg 310 lbs for EN 795 Anchorage Strength The required Anchorage Strength depends on the applicat...

Page 7: ...Force Free Fall PFAS with Shock Absorbing Lanyard 6 kN 1 350 lb Refer to the instruction s included with your Lanyard or SRD for Free Fall limitations PFAS with Self Retracting Device SRD 6 kN 1 350...

Page 8: ...NS Snap hooks and carabiners used with this equipment must be self locking Ensure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all conne...

Page 9: ...gap of 12 7 mm 1 2 in 4 0 USE 4 1 BEFORE EACH USE Verify that your work area and Personal Fall Arrest System PFAS meet all criteria defined in Section 2 and a formal Rescue Plan is in place Inspect t...

Page 10: ...ding Beam Anchor Labels must be replaced if they are not fully legible Information provided on each label is as follows A Warning Label 1 Reall all instructions 2 Maximum capacity 140 kg 3 Notified bo...

Page 11: ...Equipment Additional Personal Fall Arrest System PFAS equipment harness SRL etc that are used with the Anchorage System should be installed and inspected per the manufacturer s instructions Serial Nu...

Page 12: ...ed boret eller anordningen S rg for at faldsikringssystemer undersystemer der er samlet fra komponenter der er fremstillet af forskellige fabrikanter er kompatible og opfylder kravene i relevante stan...

Page 13: ...opssele Tabel 1 Specifikationer Systemspecifikationer Kapacitet 1 person med en samlet v gt t j v rkst j osv p h jst 140 kg 310 lb for EN 795 Forankringsstyrke Den p kr vede forankringsstyrke afh nger...

Page 14: ...der forefindes en formaliseret n dplan Inspic r det glidende I profilanker i henhold til Bruger inspektionspunkterne defineret i Inspektions og vedligeholdelseslog tabel 2 Brug ikke systemet hvis insp...

Page 15: ...dende I profilanker M rkater skal udskiftes hvis de ikke er helt l selige Hver m rkat har f lgende information A RFID m rkat B Advarselsm rkat 1 Inspic r det glidende I profilanker 2 M ikke repareres...

Page 16: ...mer PFAS seler SRL etc som bruges med forankringssystemet skal monteres og inspiceres i henhold til producentens anvisninger Serienummer numre K bsdato Modelnummer Dato for f rste brug Korrigerende fo...

Page 17: ...eme die aus Komponenten von verschiedenen Herstellern zusammengebaut werden zueinander passen und den Anforderungen von geltenden Normen einschlie lich ANSI Z359 oder anderen g ltigen Absturzsicherung...

Page 18: ...enders angebracht Tabelle 1 Spezifikationen Systemspezifikationen Tragf higkeit 1 Person mit einem Gesamtgewicht einschlie lich Kleidung Werkzeuge usw von maximal 140 kg 310 lbs entsprechend EN 795 St...

Page 19: ...n sein darf 4 0 EINSATZ 4 1 VOR JEDEM EINSATZ Stellen Sie sicher dass Ihr Arbeitsbereich und Ihre Pers nliche Schutzausr stung gegen Absturz PSAgA alle Kriterien erf llt die in Abschnitt 2 definiert s...

Page 20: ...sport Setzen Sie das Produkt keinen chemischen D mpfen aus berpr fen Sie die Komponenten nach langer Lagerung gr ndlich 7 0 ETIKETTEN Abbildung 10 zeigt eine Installation des Tr gerankers Etikette m s...

Page 21: ...tomatisch in die Z hne der Halteschiene A einrasten Etiketten Abbildung 10 berpr fen Sie ob alle Etiketten vorhanden sowie sicher befestigt und lesbar sind siehe Etiketten PSAgA und andere Ausr stung...

Page 22: ...emas subsistemas de protecci n contra ca das montados a partir de componentes hechos por distintos fabricantes son compatibles y cumplen los requisitos de las normas aplicables incluyendo los ANSI Z35...

Page 23: ...uerpo completo del usuario Tabla 1 Especificaciones Especificaciones del sistema Capacidad 1 Persona con un peso combinado ropa herramientas etc de no m s de 140 kg 310 lbs para EN 795 Resistencia del...

Page 24: ...i rese de que la zona de trabajo as como el sistema personal de detenci n de ca das PFAS cumplen todos los criterios definidos en el Apartado 2 y que existe un plan de rescate oficial previsto Revise...

Page 25: ...as etiquetas no son plenamente legibles deben sustituirse La informaci n de las etiquetas es la siguiente A Etiqueta de RFID B Etiqueta de advertencia 1 Inspeccione el anclaje deslizante para vigas 2...

Page 26: ...len autom ticamente con los dientes de la barra de soporte A Etiquetas Figura 10 Verifique que est n todas las etiquetas de seguridad y que est n correctamente fijadas y sean legibles consulte Etiquet...

Page 27: ...si j rjestelmi Varmista ett muiden valmistajien komponenteista kootut putoamisenestoj rjestelm t alij rjestelm t ovat yhteensopivia ja t ytt v t asianomaisten standardien vaatimukset mukaan lukien ANS...

Page 28: ...kaisen kiinnityselementin v liin Taulukko 1 Tekniset tiedot J rjestelm n tekniset tiedot Kapasiteetti 1 henkil jonka kokonaispaino vaatteet ty kalut jne ei ylit 140 kg standardin EN 795 mukaan Tuen va...

Page 29: ...astussuunnitelma Tarkasta liukupalkkiankkuri k ytt j n tarkastus ja kunnossapitolokissa taulukko 2 lueteltujen tarkastuspisteiden mukaisesti Jos j rjestelm n kunto m ritet n tarkastuksessa turvallisuu...

Page 30: ...tulee uusia jos ne eiv t ole t ysin luettavissa Kaikissa merkinn iss on seuraavat tiedot A RFID merkint B Varoitusetiketti 1 Tarkasta liukupalkkiankkuri 2 l korjaa Vain valtuutettu huolto saa huoltaa...

Page 31: ...rat ovat n kyvill hyvin kiinni ja luettavissa katso Merkinn t Putoamisenestoj rjestelm t ja muut laitteet Kiinnitysj rjestelm n kanssa k ytett v t ylim r iset putoamisenestoj rjestelmien laitteet valj...

Page 32: ...de divers fabricants sont compatibles et respectent les exigences des normes applicables y compris la norme ANSI Z359 ou d autres codes normes ou contraintes de protection contre les chutes Consultez...

Page 33: ...int gral de l utilisateur Tableau 1 Sp cifications Sp cifications du syst me Capacit 1 personne au poids combin v tements outils etc de 140 kg 310 lb maximum conform ment la norme EN 795 Force d ancra...

Page 34: ...ctions de poutre doivent tre de niveau avec un espace maximum de 12 7 mm 1 2 po 4 0 UTILISATION 4 1 AVANT CHAQUE UTILISATION v rifier que la zone de travail et l quipement de protection individuelle E...

Page 35: ...doivent tre remplac es si elles ne sont pas parfaitement lisibles Les informations pr sentes sur chaque tiquette sont les suivantes A Plaque d identification RFID B tiquette d avertissement 1 Inspect...

Page 36: ...position enti rement et s engagent automatiquement dans les dents du tube de support A tiquettes Figure 10 V rifiez que toutes les tiquettes sont pr sentes correctement fix es et lisibles voir tiquet...

Page 37: ...5908299 37 3 3 3M Fall Protection ANSI Z359 3 3 Top Drive Arc Flash Hot Works 3 3 GR...

Page 38: ...38 ID 2 1 DBI SALA 3M 2 1 SRD 1 1 140 kg 310 lbs EN 795 EN 795 12 kN 2698 lb 40 C 40 F 22 kN 5000 lbs 1 1 2 B 1 1...

Page 39: ...39 3 0 DBI SALA 1 2 12 3 1 2 1 1 3 2 1 1 7 8 1 2 3 14 3 mm 9 16 in 1 4 12 7 mm 1 2 in 4 0 4 1 PFAS 2 2 3 4 2 SRD 9 SRD SRD D D SRD 5 0 5 1 1 2 Radio Frequency Identification RFID RFID 1 2...

Page 40: ...40 5 2 3 3 5 3 6 0 6 1 6 2 3 3 3M 6 3 7 0 10 RFID B 1 2 3 40 C 60 C 4 5 6 7 7 8 12kN 8 12kN 9 10 11 140 kg 310 lbs 12 13 14 15 16 12kN 17 18 19 20...

Page 41: ...2 1 1 2 10 PFAS PFAS SRL 1...

Page 42: ...i sistemi sottosistemi di protezione anticaduta assemblati con componenti realizzati da produttori diversi siano compatibili e soddisfino i requisiti degli standard applicabili inclusi ANSI Z359 o al...

Page 43: ...abella 1 Specifiche Specifiche del sistema Capacit 1 persona con peso totale compresi indumenti utensili ecc non superiore a 140 kg 310 libbre per EN 795 Forza dell ancoraggio La forza di ancoraggio r...

Page 44: ...o in corrispondenza dei giunti o delle estremit della trave I giunti tra le sezioni della trave devono essere allineati con uno spazio massimo di 12 7 mm 1 2 pollice 4 0 USO 4 1 PRIMA DI OGNI USO ver...

Page 45: ...inutilizzo ispezionare attentamente i componenti 7 0 ETICHETTE La figura 10 illustra le etichette sul dispositivo di ancoraggio scorrevole Sostituire le etichette se non sono completamente leggibili...

Page 46: ...i denti della barra di supporto A Etichette Figura 10 Verificare che tutte le etichette siano presenti saldamente attaccate e leggibili vedere la sezione Etichette Sistemi di protezione anticaduta e...

Page 47: ...s gasleidingen of andere kritische materialen of apparatuur door de boor kunnen worden geraakt Zorg ervoor dat valbeveiligingssystemen subsystemen samengesteld uit onderdelen van verschillende fabrika...

Page 48: ...haamsharnas van de gebruiker Tabel 1 Specificaties Systeemspecificaties Capaciteit 1 persoon met een gecombineerd gewicht kleding gereedschap enz van niet meer dan 140 kg voor EN 795 Verankeringssterk...

Page 49: ...gingsbaan of aan de verbindingen of uiteinden van de stang kan komen Verbindingen tussen stangdelen moeten gelijk zijn met een maximale tussenruimte van 12 7 mm 4 0 GEBRUIK 4 1 VOORAFGAAND AAN ELK GEB...

Page 50: ...ende valbeveiligingsapparatuur in een koele droge en schone omgeving en uit de buurt van direct zonlicht wanneer deze niet wordt gebruikt Vermijd plekken waar chemische dampen kunnen voorkomen Inspect...

Page 51: ...n van de steunstang A grijpen Labels Afbeelding 10 Controleer of alle labels aanwezig veilig bevestigd en leesbaar zijn zie Labels PFAS en andere apparatuur Aanvullende persoonlijke valstopsysteemappa...

Page 52: ...er innretningen S rg for at fallsikringssystemer undersystemer som er satt sammen av komponenter fremstilt av forskjellige produsenter er kompatible og oppfyller kravene i gjeldende standarder inklude...

Page 53: ...rende festeelementet p brukerens fullegemesele Tabell 1 Spesifikasjoner Systemspesifikasjoner Kapasitet 1 person med samlet vekt kl r verkt y osv p ikke mer enn 140 kg 310 lbs for EN 795 Forankringsst...

Page 54: ...ikringssystemet PFAS oppfyller alle kriteriene som er definert i del 2 og at det finnes en formell redningsplan Inspiser den glidende bjelkeforankringen i henhold til Bruker inspeksjonspunkter som er...

Page 55: ...lkeforankringen Etikettene m skiftes ut hvis de ikke er fullt leselige Informasjonen p hver etikett er som f lger A RFID skilt B Varseletikett 1 Kontroller den glidende bjelkeforankringen 2 M ikke rep...

Page 56: ...ikkert festet og leselige se Etiketter PFAS og annet utstyr Ekstra personlig fallsikringssystem PFAS utstyr sele SRD osv som brukes sammen med forankringssystemet skal monteres og inspiseres i henhold...

Page 57: ...da montados com componentes produzidos por diferentes fabricantes s o compat veis e satisfazem os requisitos das normas aplic veis incluindo a ANSI Z359 ou outros c digos normas ou requisitos de prote...

Page 58: ...n s de corpo inteiro do utilizador Tabela 1 Especifica es Especifica es do sistema Capacidade 1 pessoa com um peso combinado vestu rio ferramentas etc m ximo de 140 kg 310 libras em conformidade com a...

Page 59: ...viga em qualquer ponto ao longo do percurso de movimento previsto ou nas uni es ou extremidades da viga As uni es entre as sec es da viga devem ter um afastamento m ximo de 12 7 mm 1 2 pol 4 0 UTILIZA...

Page 60: ...s componentes ap s armazenamento prolongado 7 0 ETIQUETAS A Figura 10 ilustra as etiquetas no dispositivo de ancoragem deslizante para vigas As etiquetas devem ser substitu das se n o forem completame...

Page 61: ...D funcionam livremente a mola recoloca o fecho na posi o inicial e que encaixam automaticamente nos Dentes da Barra de Suporte A Etiquetas Figura 10 Verifique se todas as etiquetas est o presentes be...

Page 62: ...eller utrustningen Se till att fallskyddssystem och delsystem som r monterade med komponenter fr n olika tillverkare r kompatibla och uppfyller kraven i till mpliga standarder inklusive ANSI Z359 ell...

Page 63: ...ppssele Tabell 1 Specifikationer Systemspecifikationer Kapacitet 1 person med totalt vikt inklusive kl dsel verktyg osv h gst 140 kg 310 pund f r att uppfylla EN 795 F rankringsh llfasthet Erforderlig...

Page 64: ...ormell r ddningsplan uppr ttats Inspektera glidbalksf rankringen enligt Anv ndarens kontrollpunkter som finns i Besiktnings och underh llsloggen tabell 2 Anv nd inte systemet om ett os kert eller defe...

Page 65: ...inte r helt l sliga F ljande information tillhandah lls p varje etikett A RFID tagg B Varningsetikett 1 Kontrollera glidbalksf rankringen 2 F r ej repareras Denna produkt m ste servas p ett beh rigt s...

Page 66: ...ketter sitter s kert fast och r l sbara se Etiketter PFAS och vrig utrustning Ytterligare utrustning f r personligt fallskyddssystem PFAS sele SRL osv som anv nds tillsammans med f rankringssystemet s...

Page 67: ...OTTOJEN MENETT MINEN MILL N TAVALLA TUOTTEISIIN LIITTYEN OIKEUSTEORIASTA HUOLIMATTA GARANTIE PRODUIT INTERNATIONALE RECOURS LIMIT ET LIMITATION DE LA RESPONSABILIT GARANTIE LES DISPOSITIONS SUIVANTES...

Page 68: ...m Japan 3M Japan Ltd 6 7 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M...

Reviews: