Table of Contents
Safety Information ...........................................................................1
Dual Flow (DF) Manifold Systems and Cartridges ............................3
Inlet and Outlet Connections ............................................................3
Product Dimensions ........................................................................3
How to Use “Push-in” Connections .................................................4
How to Use “Inlet/Outlet” Fitting Retention Clips .............................4
Equipment Installation .....................................................................5
Cartridge Change-out Procedure .....................................................6
Troubleshooting ...............................................................................7
Replacement Parts Listing ...............................................................7
Limited Warranty .............................................................................8
Dual Flow (DF) Manifold System and Cartridges
The DF260-CL-CC Dual Flow (DF) System helps to provide consistent high quality water for multiple applications. The inlet water for the ice machine
enters the manifold on the left rear side, and the inlet water for the beverage and coffee enters the manifold on the right rear side. Each water
stream (ice, beverage, coffee) has a separate outlet connection fi tting.
The left single cartridge (yellow label) is model HF60-S-SR5. It is critical that this cartridge be installed in the left most manifold head which
also has a yellow 3M label. The cartridge is keyed such that it will not fi t properly if installed in either of the other manifold heads. The media in
this cartridge is a pleated nylon membrane with a time released scale inhibitor. It fi lters the water going to the ice machine. The water for the ice
machine exits the manifold on the left side front connection (labeled “Outlet Ice”).
The two cartridges to the right of the ice cartridge (blue label) are model HF60-CL. These cartridges are plumbed in parallel and fi lter the water
going to post mix cold beverage and coffee. The HF60-CL cartridges will not fi t into the left most (ice) head. The water for cold beverage exits the
manifold on the middle front connection (labeled “Outlet Beverage”). Water for coffee exits the manifold on the right side front connection (labeled
“Outlet Coffee”).
Inlet and Outlet Connections
The water inlets are on the rear left and right sides, and the water outlets are on the front right, middle, and left sides. All inlets and outlets are
identifi ed with their corresponding labels. The water inlets fi tting size is ¾” NPT male, the ice and beverage outlet fi tting size is ½” barb, and the
coffee outlet fi tting size is ¾” NPT female. Built-in check valves (non-return) are incorporated into all three outlets.
Product Dimensions
OUTLET
TO ICE
TOP VIEW
OUTLET
TO BEVERAGE
18 3/4"
47.6 cm
25 9/16"
[64.9 cm]
REQUIRED TO REMOVE CARTRIDGE
3" MINIMUM DISTANCE
3
Figure 1