How To Use “Push-In” Fittings (Collet)
CAUTION
CAUTION
To reduce the risk associated with property damage due to water leakage:
•
Do not install
unit if collet is missing. Contact your sales representative if collets are missing from any fi ttings.
This product is outfi tted with user friendly “push-in” connectors. Proper use of the connectors is shown in Figure 2. It is most important that the
tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary
to cut the tubing, use a plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a “push-in” connector, the cause
is usually due to the tubing. To fi x tubing, relieve the pressure within the tube. Release the end of the tubing with the leak from its
“push-in” connector. Cut off at least 1/4” (0.6 cm) from the end. Reattach the tubing to its “push-in” connector. Confi rm connection is leak free.
How to Use the Inlet/Outlet Fitting Retention Clips
This product is outfi tted with inlet/outlet fi ttings. The fi ttings can be attached or removed from the system without tools. Retention clips are semi-
circular in shape with three internal tabs, bottom, center and top. Tab interlaces with windows in the manifold head near each connection port. Clip
is fl exible and easily assembled following these instruction and illustrations.
1. Insert fi tting into manifold.
2. With fi tting inserted into manifold port, snap clip into place beginning at the bottom slot.
3. Push center tab into center slot.
4. Finally push top tab into top slot.
Step 2
Step 3
Step 4
Step 1
To Attach Tubing
To Release Tubing
Push tubing straight as far as it will go.
1
1
2
2
Tubing is secured in.
Push in grey collet to release tubing.
Pull tubing straight out.
4
Figure 2
Figure 3
Summary of Contents for DF260-CL-CC