17
5.0 MAINTENANCE, SERVICE, and STORAGE
;
Do not clean or disinfect the product by any method other than described in the following cleaning instructions. Other
methods may have adverse effects on the product or user.
5.1 CLEANING:
3M full body harnesses must be cleaned in accordance with 3M instructions. To clean the harness, wash in
a mild, bleach-free detergent and then rinse. The harness should afterwards be hung to air-dry. Water used for cleaning
and temperatures used to air-dry should never exceed 130
°
F (54.4
°
C). For more information, please refer to the technical
bulletin on our website:
http://www.3M.com/FallProtection/WebCleaning
;
For any questions about cleaning procedures, please contact 3M Technical Services.
5.2
AUTHORIZED SERVICE:
Additional maintenance and servicing procedures must be completed by a factory authorised
service center. Authorisation must be in writing. Do not attempt to disassemble the unit.
5.3
STORAGE AND TRANSPORT:
Store and transport the ExoFit Nex Full Body Harness in a cool, dry, clean environment
out of direct sunlight. Avoid areas where chemical vapors may exist. Thoroughly inspect the harness after extended
storage.
6.0 LABELS
and MARKINGS
6.1 LABELS:
Figure 15 illustrates product labels and their location on the ExoFit Nex Full Body Harness. All labeling must be
present and fully legible. Information on each label is as follows:
A
1) Part Number
2) Serial Number
3) Lot Number
4) Date of Manufacture
5) Date to be Destroyed
B
1) Read all instructions.
2) Mark of Certification
3) Applicable Standards
4) Harness Donning Instructions - Vest Style
5) Inspection Log
C
1) Read all instructions.
2) Mark of Certification
3) Applicable Standards
4) Harness Donning Instructions - Crossover Style
5) Inspection Log