7
78-8136-3182-3
3. Specifications
Dimensions:
Base unit: (152 x 152 x 152) mm
(6 x 6 x 6) inches
Weight:
1,6 kg (3.53 lbs.)
High voltage cascade:
> 1100 V positive or negative (current limiting
resistor: 10 M
Ω
)
Power supplies:
Built-in NiMH-rechargeable batteries, 1400 mAh -
Recharge time approximately 14 hours (unit off) when
batteries are fully discharged
AC adaptor: secondary side, DC 12 V/500 mA
Operating time (rechargeable batteries):
2 hours (approx.) with full charge.
1.5 hours (approx.) when using Remote Field Sensor
Storage memory capacity:
128 k EEPROM (e.g. sufficient for approximately 100
CPM-measurements)
Response time:
0 to 100 % _ 100 ms
Impedance:
10
15
Ω
(Teflon-separators cleaned)
Accuracy:
± 2.5 % of range end value (digitized)
Analog Output
± 10% 25, 100, 500, & 5,000 VDC
± 5 % 1,000 VDC
Operating functions:
CPM (positive/negative/automatic), Voltmeter, and
Fieldmeter
Interfaces:
Analog output ± 2v (± 1 V, in 500v range for
voltmeter).
Input to output ratio in Voltmeter Mode: 25vdc = 12.5
to 1, 100vdc = 50 to 1, 500vdc = 500 to 1, 1,000vdc =
500 to 1, 5,000vdc = 2500 to 1.
Serial PC-COM RS232
Remote Field Sensor Probe, Model 711 RS:
34mm diameter - 190 gms (6.7 oz.)
Measurement Ranges:
Distance/Voltage/Resolution
1 cm (0 to 10kv) 1V
2,5 cm (0 to 20kv) 2V
5 cm (0 to 50kv) 10V
10 cm (0 to 100kv) 10V
20 cm (0 to 200kv) 20V
Displays:
Two, 11-segment positive & negative LED-bar charge
indicators
16-digit alphanumeric dual row LCD
Settings: CPM - operating function:
Starting voltage: 600 V - 1200 V in 1 V-steps
Stop voltage: 1 V - 500 V in 1 V-steps
(in decimal mode)
Static decay time:
0.1 seconds - 99.9 seconds
Offset-voltage time:
0 seconds (Indefinite time, CPM in floating mode)
1 - 10 seconds (1 second steps)
10 - 60 seconds (10 second steps)
Voltmeter operating function:
Ranges: 25 V, 100 V, 500 V, 1.0 kV,
5.0 kV and auto range
Fieldmeter operating function:
Ranges: Manual 1.25 kV/m, 5 kV/m, 25 kV/m,
50 kV/m, 250 kV/m, and automatic
Plate electrode:
VA-steel (152 x 152) mm/(6 x 6) inches, removable,
capacitance (20 ± 2) pF
Cup electrode:
Gold-plated electrode with 4mm-banana socket, for
voltage measurements
Selection of operating function:
Pre-setting is “FIELDMETER”, additional automatic
settings by applying the plate or cup electrode
Operating temperature:
0 to 45°C (32º F to 113º F)
Humidity:
Maximum 60 %
Note: At high relative humidity, charge leakage may
occur affecting the decay time measurement.
Storage temperature:
-30˚ C to 60° C (-22˚ F to 140˚ F)
Declaration of conformity
EN 60204-1/85
EN 60204-1/91
EN 61010 (SAFETY)
EN 50082-1
EN 50082-2