background image

SAFETY INFORMATION

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

CAUTION

IMPORTANT NOTES

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the 

Aqua-Pure

®

 AP800 Series Whole House Water Filters. Retain these instructions for future reference.

Intended use:

The Aqua-Pure

®

 AP800 Series Whole House Water Filters are intended for use in filtering potable water in homes and have not 

been evaluated for other uses.  These filters are typically installed at the point of entry, and should be installed by qualified 

professional installers according to these installation instructions.

CAUTION

WARNING

Indicates a potentially hazardous situation, which, if not avoided, could result in death or 

serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or 

moderate injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

To reduce the risk associated with choking:

  • 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

  • 

Do not

 use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after 

the system.

To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or 

water pipes in the area of installation:

  • 

Do not

 install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to 

mount the filter bracket.

To reduce the risk of physical injury:

  • Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.

To reduce the risk associated with a hazardous voltage:

  • If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper 

must

 be used 

to ensure a sufficient ground connection across the filter installation piping — refer installation to qualified personnel.

To reduce the risk associated with back strain:

  • Follow safe lifting procedures.

To reduce the risk associated with property damage due to water leakage:

• 

Read and follow

 Use Instructions before installation and use of this system.

•  Installation and use 

MUST

 comply with all state and local plumbing codes.

• 

Protect from freezing

. Drain filter when temperatures are expected to drop below 40°F (4.4°C).

• 

Do not

 install systems in areas where ambient temperatures may go above 110° F (43.3° C).

• 

Do not

 install if water pressure exceeds 100 psi (690 kPa). If your water pressure exceeds 80 psi (552 kPa), you 

must

 

install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

• 

Do not 

install where water hammer conditions may occur. If water hammer conditions exist you must install a 

water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

•  Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal 

expansion must be installed.

• 

Do not install on hot water supply lines.

 The maximum operating water temperature of this system is 100°F (37.8°C).

• 

Do not

 use a torch or other high temperature sources near system, cartridges, plastic fittings or plastic plumbing.

•  On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape 

only

, pipe dope properties may 

deteriorate plastic.

•  Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs.

• 

Do not 

install in direct sunlight or outdoors.

• 

Do not 

install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.

•  Mount system in such a position as to prevent it from being struck by other items used in the area of installation.

•  Ensure that the location and fasteners will support the weight of the system when installed and full of water.

• 

Ensure

 all tubing and fittings are secure and free of leaks.

•  SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is shut off.

•  The disposable cartridge must be replaced every 6 months, at the rated capacity or sooner if a noticeable reduction 

in flow rate occurs.

•  Failure to follow instructions will void warranty.

•  Allow a minimum of 2” (5.1 cm) clear space under filter to facilitate cartridge change.

•  Install with the inlet and outlet ports as labeled.  Make sure not to reverse connections.

•  Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line.

•  Before starting installation, shut off main water supply and drain pipes.

CAUTION

2

Summary of Contents for Aqua-Pure AP801 Housing

Page 1: ...use Water Filters AP800 Series Models AP801 Housing AP801 C System AP802 Housing Installer Please leave manual with homeowner Homeowner For complete information on system operation maintenance and warranty please retain Installation and Operating Manual ...

Page 2: ......

Page 3: ... Use Instructions before installation and use of this system Installation and use MUST comply with all state and local plumbing codes Protect from freezing Drain filter when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install if water pressure exceeds 100 psi 690 kPa If your water pressure exceeds 80...

Page 4: ...ny tools listed here A Pipe Cutter B Two 1 Male Compression Adapters C 1 Ball Valve Compression Type D PTFE Tape E Adjustable Wrench F Aqua Pure AP810 filter cartridge Included with AP801 C model only see page 5 for cartridge options G Ground Kit not shown GETTING STARTED A B B C D E F 1 2 3 City Water Installation Well Water Installation Meter Master Shut Off Valve To Household Plumbing Pump Mast...

Page 5: ... housing 8 Place cartridge into housing Install housing onto head 9 Slowly turn on main water supply Press red air release button on filter head to expel air 10 Check for leaks 11 Flush at least 10 5 gallons through system CAUTION WARNING To reduce the risk associated with hazardous voltage If the home electrical system requires use of the cold water system as an electrical safety ground a jumper ...

Page 6: ...is warranty does not cover failures result ing from abuse misuse alteration or damage not caused by 3M Purification Inc or failure to follow installation and use instructions No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and water consumption 3M PURIFICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED ...

Page 7: ... producto en lugares donde puedan provocarse golpes de ariete Si existen las condiciones para que se produzca un golpe de ariete debe instalar un supresor de golpes de ariete Póngase en contacto con un plomero profesional si no está seguro de cómo identificar esta situación Si hay un dispositivo contra reflujo instalado en el sistema de agua deberá instalar también un dispositivo para controlar la...

Page 8: ... tubos B Dos adaptadores de compresión macho de 1 pulgada C Válvula tipo bola de 1 pulgada tipo de compresión D Cinta PTFE E Lleve de ajuste F Cartucho de filtro Aqua Pure AP810 incluido con el modelo AP801 C únicamente consulte la página 5 para ver las opciones de cartuchos G Kit de Tierra no aparece PARA COMENZAR A B B C D E F 1 2 3 Instalación en Agua Municipal Instalación en Agua de Pozo Medid...

Page 9: ...e manera firme 8 Coloque el cartucho en la carcasa Instale la carcasa en el cabezal 9 Abra lentamente la entrada principal de agua Oprima el botón rojo de liberación del aire en el cabezal del filtro para eliminar el aire 10 Compruebe si hay fugas 11 Irrigue al menos 10 5 galones a través del sistema IMPORTANTE INSTRUCCIONES PARA LA INSTALACIÓN Para reducir el riesgo asociado con voltajes peligro ...

Page 10: ...de defectos en los materiales y la mano de obra durante diez 10 años desde la fecha de compra Esta garantía no cubre las fallas originadas por el abuso el uso inadecuado la alter ación o el daño no ocasionado por 3M Purification Inc o por el incumplimiento de las instrucciones de instalación y uso No se ofrece ninguna garantía en lo referido a la vida útil de cualquier cartucho o membrana del filt...

Page 11: ...s installer sur une tuyauterie sujette aux coups de bélier Un dispositif antibélier doit être installé s il existe des conditions sujettes aux coups de bélier Communiquer avec un plombier professionnel pour toute incertitude concernant cette situation Lorsqu un dispositif de prévention de retour d eau est installé sur un réseau d alimentation en eau la dilatation thermique doit être réglée par l i...

Page 12: ... tuyau B Deux adaptateurs mâles à compression de 1 po C Clapet à bille de 1 po à compression D Ruban de PTFE E Clé réglable F Cartouche filtrante Aqua Pure modèle AP810 comprise avec le modèle AP801 C uniquement consultez la page 5 pour connaître les options de cartouches G Kit de Terre non illustré DÉMARRAGE A B B C D E F 1 2 3 Installation avec eau d aqueduc Installation avec eau de puits Compte...

Page 13: ...he dans le boîtier Installer le boîtier sur la tête 9 Ouvrir lentement le robinet d alimentation en eau Appuyer sur le bouton de décompression rouge sur la tête du filtre pour expulser l air 10 Vérifier toute trace de fuite 11 Faire une chasse d au moins 40 litres 10 5 gallons dans le système Pour réduire les risques associés aux tensions dangereus es causées par le perçage à travers du filage éle...

Page 14: ...de matériel et de main d oeuvre pour une période de dix 10 ans à partir de la date de l achat Cette garantie ne couvre pas les défectuosités occasionnées par une utilisation abusive ou le mésusage l altération ou le dommage non occasionné par 3M Purification inc ou le défaut de respecter les instructions d installation et d utilisation Aucune garantie n est fournie pour la durée de vie utile de to...

Page 15: ...NOTES 14 ...

Page 16: ...6450 U S A Toll Free 800 222 7880 Worldwide 203 237 5541 Fax 203 238 8701 www aquapure com www 3Mpurification com 3M is a trademark of 3M Company Aqua Pure is a trademark of 3M Company used under license 2013 3M Company All rights reserved INSTRAP801 0613 ...

Reviews: