SAFETY INFORMATION
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
CAUTION
IMPORTANT NOTES
Read, understand, and follow all safety information contained in these in-
structions prior to installation and use of the AP717 In-Line Filtration Sys-
tem. Retain these instructions for future reference.
Intended use:
The AP717 systems are intended for use in fi ltering potable water in homes and have not
been evaluated for other uses. The system is typically connected to a refrigerator, and
should be installed by qualifi ed professional installers according to these installation
instructions.
C
CAUTION
WARNING
Indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided,
may result in property damage.
To reduce the risk associated with ingestion of contaminants due to use with water that is
microbiologically unsafe or of unknown quality:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
To reduce the risk associated with property damage due to water leakage:
•
Read and follow
Use Instructions before installation and use of this system;
• Installation and Use
MUST
comply with all state and local plumbing codes.
•
Protect from freezing
. Drain system when room temperature drops below 33°F (0.6°C);
•
Do not
install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 125
psi, you
must
install a pressure limiting valve. Contact a plumbing professional if you are uncer-
tain how to check your water pressure.
•
Do not
install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how
to check for this condition.
• Install
on
COLD
water lines only (33-100°F (0.6-37.8°C));
• The disposable fi lter cartridge
must
be replaced every six months or at the specifi ed ser-
vice cycle.
•
Do not
use torch or other high temperature sources near fi lter or plastic fi ttings.
• Mount
fi lter in such a position as to prevent it from being struck by other items used in the area of
installation (waste baskets, etc).
• On plastic fi ttings, never use pipe sealant or pipe dope. Use thread sealing tape
only.
•
Do not
install in direct sunlight.
•
Do not
install unit if collet is missing. Contact CUNO if collets are missing from any fi ttings.
•
Ensure
all tubing and fi ttings are secure and free of leaks.
•
SHUT OFF FUEL SUPPLY TO WATER HEATER
after water is shut off.
• Failure to follow instructions may void warranty.
• Allow a minimum of 6” (15.24 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.