CAUTION    

• The 963 is designed for use in those areas using AC 120V electrical service,

while the 963E runs off of DC24V power, supplied by a universal power
supply capable of converting AC 100-240V electrical service.  Usage of
either unit with the incorrect electrical voltage could result in incorrect
performance and an unsafe operating condition.

• The 963/963E has no user-serviceable parts. Do not remove the grill or

disassemble the unit in any way.  If service other than that recommended in
this manual is needed, please contact 3M for information.  UNAUTHORIZED
SERVICE WILL VOID THE WARRANTY.

• The 963/963E is NOT designed for usage in hazardous environments where

the possibility of explosion or fire exists.

• When cleaning the 963/963E housing or emitter points, verify that the unit is

off and disconnected from electrical power. Collected dirt on this unit should
be removed regularly to prevent accumulation that may result in fire.

• Class 1 equipment.

Explanation of Symbols

– Caution: refer to user instruction manual.

– High voltage present inside unit.

Read and understand all safety information before installing and operating this
equipment.

Safety Information

Intended Use

The 3M™ 963/963E Benchtop Air
Ionizer is designed to generate and
deliver a stream of ionized air.  Its
intended use is to neutralize excess
static electricity buildup on electronic
devices and work surfaces.  It is meant
to function as a stand alone device.

The 963/963E Benchtop Air Ionizer is
not intended to supplant proper
grounding of personnel as the
preferred method of controlling
electrostatic buildup and preventing
hazardous discharge.

Summary of Contents for 963

Page 1: ...3 963 963E Benchtop Air Ionizer Instructions ...

Page 2: ...age Safety Information 4 1 Description 5 2 Performance 5 3 Power Requirements 5 4 Installation 5 5 Operation 6 6 Maintenance 6 7 Performance Verification 7 8 Physical Characteristics 8 9 Customer and Technical Service 9 ...

Page 3: ...ts When cleaning the 963 963E housing or emitter points verify that the unit is off and disconnected from electrical power Collected dirt on this unit should be removed regularly to prevent accumulation that may result in fire Class 1 equipment Explanation of Symbols Caution refer to user instruction manual High voltage present inside unit Read and understand all safety information before installi...

Page 4: ...ican style three prong plug The 963E requires DC 24V power which is supplied through a Mini DIN connector on the back of the unit The 963E is packaged with a universal power supply capable of converting AC 100V 240V 50 60 Hz into DC 24V The universal power supply uses a 3 0 9 m cord to connect to the ionizer and has an IEC 320 input socket for incoming power Please note that due to the multitude o...

Page 5: ...of the ON positions and that the ionizer is now in use Section 6 Maintenance Occasional cleaning of the case and of the emitter points are the only routine maintenance procedures required 6 1 Cleaning the case wipe the case with a soft cloth moistened with water If a stronger cleaning solution is required mild detergent or alcohol may be used Do not use solvents that will attack the plastic case 6...

Page 6: ...e foot The plate of the 711 should be centered up down left right in the air stream It may be necessary to raise the ionizer from the surface to allow for centering on the 711charge plate If so use a block of appropriate height to elevate the 711 Please note that the plate must be kept totally isolated from ground and that the edge of the plate should be raised up a minimum distance of 3 inches fr...

Page 7: ...ni DIN plug Power Outlet Cord 6 1 8m cord with IEC 320 Not Included and NEMA 5 15 plugs Dimensions 7 0 W x 9 H x 4 D 7 0 W x 9 H x 4 D w mounting base 18 cm W x 23 cm H x 10 cm D 18 cm W x 23 cm H x 10 cm D Weight 2 5 lb 1 1 kg 2 5 lb 1 1 kg Air Volume low speed 68 SCFM 1 92 m3 min 76 SCFM 2 15 m3 min high speed 105 SCFM 2 97 m3 min 112 SCFM 3 17 m3 min Static discharge time 1 ft 30 cm 1 second 1 ...

Page 8: ... can be obtained by calling the 3M Electronic Handling Protection Division Customer Service 800 328 1368 Technical Support 512 984 3200 Outside of the U S For customer service and technical support please contact your local representative of the 3M Electronic Handling Protection Division ...

Page 9: ...10 ...

Page 10: ... Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESS AND IMPLIED INCLUDING FITNESS AND MERCHANT ABILITY The express warranty will not apply to defects of damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability In no event will 3M or Seller be responsible or liable for...

Page 11: ...Litho in the USA 3M 2000 34 7049 7753 6 Recycled paper 40 pre consumer 10 post consumer 3 Electronic Handling Protection Division 6801 River Place Blvd Austin TX 78726 9000 800 328 1368 www 3m com ehpd ...

Reviews: