Description

The 3M 963/963E Benchtop Air
Ionizer is a self-contained ionizing air
blower designed to remove static
charges from non-conductive objects.
The proprietary circuitry contained in
the blower generates equal levels of
positive and negative ions, and
maintains correct balance despite
variations in line voltage, fan speed,
and emitter point condition.  The
963/963E is equipped with a two-
speed fan which allows the user to
select the amount of ionized air to be
delivered to the target object.  In
addition, the housing of the 963/963E
is constructed of a static-dissipative
plastic, which minimizes the amount
of static charge that can buildup on the
outside surface of the unit.

Section 2.
Performance

The 963/963E Benchtop Air Ionizer
reduces a static charge of ± 1000 V to
± 100 V in less than one second (the
discharge time) at a distance of one
foot (30 cm) using the high fan speed.
Testing is performed in accordance
with the ionization standard
ANSI/ESD S3.1 and IEC standard
61340-5-1. 

Section 3.
Power Requirements

The 963 requires AC 120V power and
is supplied with a 6 ft. (1.8 m) power
cord with North American style three-
prong plug.  The 963E requires DC

24V power, which is supplied through
a Mini DIN connector on the back of
the unit.  The 963E is packaged with a
universal power supply, capable of
converting AC 100V-240V, 50/60 Hz
into DC 24V.  The universal power
supply uses a 3' (0.9 m) cord to
connect to the ionizer, and has an IEC
320 input socket for incoming power.
Please note that, due to the multitude
of locations worldwide in which the
963E can be used, it does NOT come
supplied with a power cord to connect
the universal power supply to local
electrical service.  The customer is
asked to please provide an appropriate
power cord that is capable of
connecting local electrical service to
the universal power supply.

Section 4.
Installation

4.1 The 3M 963/963E Benchtop Air

Ionizer mounts easily in a variety
of positions using the provided
tilting bracket/stand.  Place the
unit on the work surface and point
it at the area or object to be
neutralized.  Alternatively, the
mounting bracket may be attached
directly to or above the
workstation, or on another
supporting structure. Please note
that placement of the 963/963E is
important in determining its
effectiveness.   The distance from
the target object, and fan speed
affect the ionizer’s performance.
As distance increases or fan speed
is reduced, the discharge time will
increase.

Summary of Contents for 963

Page 1: ...3 963 963E Benchtop Air Ionizer Instructions ...

Page 2: ...age Safety Information 4 1 Description 5 2 Performance 5 3 Power Requirements 5 4 Installation 5 5 Operation 6 6 Maintenance 6 7 Performance Verification 7 8 Physical Characteristics 8 9 Customer and Technical Service 9 ...

Page 3: ...ts When cleaning the 963 963E housing or emitter points verify that the unit is off and disconnected from electrical power Collected dirt on this unit should be removed regularly to prevent accumulation that may result in fire Class 1 equipment Explanation of Symbols Caution refer to user instruction manual High voltage present inside unit Read and understand all safety information before installi...

Page 4: ...ican style three prong plug The 963E requires DC 24V power which is supplied through a Mini DIN connector on the back of the unit The 963E is packaged with a universal power supply capable of converting AC 100V 240V 50 60 Hz into DC 24V The universal power supply uses a 3 0 9 m cord to connect to the ionizer and has an IEC 320 input socket for incoming power Please note that due to the multitude o...

Page 5: ...of the ON positions and that the ionizer is now in use Section 6 Maintenance Occasional cleaning of the case and of the emitter points are the only routine maintenance procedures required 6 1 Cleaning the case wipe the case with a soft cloth moistened with water If a stronger cleaning solution is required mild detergent or alcohol may be used Do not use solvents that will attack the plastic case 6...

Page 6: ...e foot The plate of the 711 should be centered up down left right in the air stream It may be necessary to raise the ionizer from the surface to allow for centering on the 711charge plate If so use a block of appropriate height to elevate the 711 Please note that the plate must be kept totally isolated from ground and that the edge of the plate should be raised up a minimum distance of 3 inches fr...

Page 7: ...ni DIN plug Power Outlet Cord 6 1 8m cord with IEC 320 Not Included and NEMA 5 15 plugs Dimensions 7 0 W x 9 H x 4 D 7 0 W x 9 H x 4 D w mounting base 18 cm W x 23 cm H x 10 cm D 18 cm W x 23 cm H x 10 cm D Weight 2 5 lb 1 1 kg 2 5 lb 1 1 kg Air Volume low speed 68 SCFM 1 92 m3 min 76 SCFM 2 15 m3 min high speed 105 SCFM 2 97 m3 min 112 SCFM 3 17 m3 min Static discharge time 1 ft 30 cm 1 second 1 ...

Page 8: ... can be obtained by calling the 3M Electronic Handling Protection Division Customer Service 800 328 1368 Technical Support 512 984 3200 Outside of the U S For customer service and technical support please contact your local representative of the 3M Electronic Handling Protection Division ...

Page 9: ...10 ...

Page 10: ... Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESS AND IMPLIED INCLUDING FITNESS AND MERCHANT ABILITY The express warranty will not apply to defects of damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability In no event will 3M or Seller be responsible or liable for...

Page 11: ...Litho in the USA 3M 2000 34 7049 7753 6 Recycled paper 40 pre consumer 10 post consumer 3 Electronic Handling Protection Division 6801 River Place Blvd Austin TX 78726 9000 800 328 1368 www 3m com ehpd ...

Reviews: