Instruction Manual

3

718 Static Sensor

Safety Information

Intended Use

The 3M™ 718 Static Sensor is a portable,
handheld instrument designed for measuring
voltages associated with electrostatic charge.
Its intended use is for measuring the amount
of voltage, in a range from 0-20 kilovolts,
associated with an electrostatic charge
buildup on a surface.  Any deviation from
this intended use could impair the
instrument’s effectiveness and possibly lead
to an unsafe operating condition.

The 3M™ 718A Air Ionizer Test Kit is a 
set of accessories for use in conjunction 
with the 3M 718 Static Sensor.  Their
intended use is for verifying the operation of
air ionizers by measuring the neutralization 
time for a static charge placed on a
stationary metal plate. Any deviation 
from this intended use could impair the
instrument’s effectiveness and possibly lead
to an unsafe operating condition. 

Caution Statements

• The 718 Static Sensor and 718A Charger

use DC 9V power supplied by a 9V
alkaline battery.  Usage of any other
power source may cause damage to the
instruments.

• The 718 Static Sensor and 718A Air

Ionizer Test Kit have no user-serviceable
parts.  Do not disassemble the products for
any reason.  UNAUTHORIZED SERVICE WILL VOID THE WARRANTY.

• The 718 and 718A are NOT designed for usage in hazardous environments where the

possibility of explosion or fire exists.

Read and understand all safety information before installing and operating 
this equipment.

Summary of Contents for 718

Page 1: ...fying the operation of air ionizers by measuring the neutralization time for a static charge placed on a stationary metal plate Any deviation from this intended use could impair the instrument s effec...

Page 2: ......

Page 3: ...lied by a 9V alkaline battery 2 2 To install the battery on either unit 2 2 1 Remove the battery cover located in the lower back of the unit To do this press down on the cover and slide it downward 2...

Page 4: ...ront of the sensor are lit To shut off the 718 Static Sensor momentarily press down on the membrane switch labeled POWER Determining that the power is off can be verified by seeing that the liquid cry...

Page 5: ...ight emitting diodes LED s are present on the front face of the instrument These LED s emit two red bullseye targets on the surface of the object being measured As the instrument gets closer to the on...

Page 6: ...disabled The Automatic Shut Off feature will reset itself the next time the instrument is turned on 4 0 Operation and Use of the 718A Air Ionizer Test Kit It is recommended that the user be familiar...

Page 7: ...er s operating manual or consult with the ionizer manufacturer to determine what this offset balance should be 5 0 Service Calibration 5 1 Service and Repair in the event that you believe the 718 Stat...

Page 8: ...he stand to ground 5 5 3 Turn on the 718 Static Sensor and set it to the 2 kV range 5 5 4 Ground the plate Zero the display 5 5 5 Remove the ground from the plate and connect it to the high voltage po...

Page 9: ...ge Automatic Shut off 20 minutes after last switch activity Operating Time for Battery Greater than 50 hours with new battery 21 C Continuous usage Distance Indicator LED targets Aligned targets indic...

Page 10: ...ual 1 ea Certificate of Conformance 8 0 Contact Information Customer and Technical Service Within the U S Customer service and technical support can be obtained by calling the 3M Electronic Handling P...

Page 11: ......

Page 12: ...less expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one ye...

Reviews: