3M

 Indoor/Outdoor Integrated 

Protection Terminals 4990IPT

Indoor/Outdoor Building Entrance Terminal with  

the 3M

 Quick Connect System (QCS) 2814

Instructions

Underwriters Laboratories (UL 348X) Listed

October 2016

78-0015-3160-3-A

Summary of Contents for 4990IPT

Page 1: ...tdoor Integrated Protection Terminals 4990IPT Indoor Outdoor Building Entrance Terminal with the 3M Quick Connect System QCS 2814 Instructions Underwriters Laboratories UL 348X Listed October 2016 78 0015 3160 3 A ...

Page 2: ... c Insulated 6 ground wire for entrance d Internal bottom mounted three point ground bar e Binding post log label f 3M Single Pair Test Probe 2827 g Lockable protective cover 1 2 3M Integrated Protection Terminal Dimensions Model Height Width Depth 4990IPT 100 13 330 mm 13 5 343 mm 6 152 mm 3M Indoor Outdoor Integrated Protection Terminal 4990IPT 100 pair 1 3 Protector Specifications Use only UL R...

Page 3: ...estors useless 2 2 Remove the outer door and open the splicing chamber by removing the chamber cover 2 3 In the upper right corner and lower right corner remove the 2 screws holding the front panel to the enclosure Remove the front panel assembly and set aside 2 4 Mount the terminal in the desired location utilizing the keyholes on the back of the enclosure 2 5 Route connector harness tails and gr...

Page 4: ...3 12 Use 3M Cable Ties or equivalent cable ties to secure the entrance cable to the base of the splice chamber 3 13 Route cable binders to appropriate block tails and splice per your company practice 3 14 Bundle splice conductors and place inside splice chamber 3 15 Replace splice chamber cover 4 0 Installing or Replacing the Electrical Protectors Note Use only UL Recognized 3M Single Pair Protect...

Page 5: ...ch firmly into place 5 3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways Cut jumper wires to appropriate length leaving at least 2 51 mm of slack 5 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 5 1 and 5 2 5 5 Terminate additional jumper wires by repeating the abo...

Page 6: ... 50 24 SC Harness XP Pair 1 50 with SC modules 80 6114 XXXX X 1 Communication Markets Division 6801 River Place Blvd Austin TX 78726 9000 Phone 1 800 426 8688 Web www 3M com Telecom Please recycle Printed in USA 3M 2016 All rights reserved 78 0015 3160 3 A 3M Scotchlok and MS2 are trademarks of 3M Company Important Notice All statements technical information and recommendations related to 3M s pro...