6.0 3M

 Quick Connect System (QCS) 2814 Ordering Information

Product Number

Product Description

3M ID

Minimum Order

Blocks and Frames

2814AG

QCS-B block Punch-down (gelled) with no ground bar

XS-0038-4141-7

200

2814BG

QCS-B block Tool-less (gelled) with no ground bar

XS-0038-8785-7

200

2811F100-30P

QCS Frame, 30 mm pitch, 100-pair

80-6114-8013-0

1

2811F100MB

Wall-mount brackets for QCS frame

80-6114-8014-8

1

Protectors

2814SPG-3-350V

350V Single Pair Protector (gelled), 3-point

80-6114-6790-2

50

Accessories

2814GB

Ground Bar Assembly for QCS 2814

XS-0038-4143-3

200

2810LT-BLGR1-1800

QCS tagging labels (blue/green), 1-1800

80-6113-8034-8

5

2810LT-BLGR1801-3600

QCS tagging labels (blue/green), 1801-3600

80-6113-8035-5

5

2810LT-BLGR3601-6000

QCS tagging labels (blue/green), 3601-6000

80-6113-8036-3

5

2810PC-P

Purple priority cap

XS-0038-8516-6

100

2810PC-R

Red priority cap

XS-0038-7407-9

100

2810PC-Y

Yellow priority cap

XS-0038-0280-7

100

2810RC-0

Orange replacement cap

XS-0038-7406-1

100

2810RC-P

Purple replacement cap

XS-0038-8599-2

100

2827

Single-pair test probe

XS-0038-74087

1

SOR OC

Cable wire termination--SOR OC

FQ-1000-2482-4

1

2814 PC

Pair Cover

XE-0042-0953-4

100

2814XPH-QCSHC/25/24 GBM

Harness XP Pair 26-50 with GBM module

80-6114-XXXX-X

1

2814XPH-QCSHC/25/24 SC

Harness XP Pair 26-50 with SC modules

80-6114-XXXX-X

1

2814XPH-QCSHC/50/24/GBM

Harness XP Pair 1-50 with GBM modules

80-6114-XXXX-X

1

2814XPH-QCSHC/50/24/SC

Harness XP Pair 1-50 with SC modules

80-6114-XXXX-X

1

Communication Markets Division

6801 River Place Blvd.

Austin, TX 78726-9000

Phone   1-800-426-8688

Web   www.3M.com/Telecom

Please recycle. Printed in USA © 3M 2016.  

All rights reserved. 78-0015-3160-3-A

3M, Scotchlok and MS

2

 are trademarks of 3M Company.

Important Notice

All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the 

accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended 

application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current 

publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an 

authorized officer of 3M.

Warranty; Limited Remedy; Limited Liability. 

This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 

3M MAKES NO OTHER 

WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE. 

If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 

3M product or refund the purchase price of the 3M product. 

Except where prohibited by law, 3M will not be liable for any direct, indirect, special, 

incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted.

 

Summary of Contents for 4990IPT

Page 1: ...tdoor Integrated Protection Terminals 4990IPT Indoor Outdoor Building Entrance Terminal with the 3M Quick Connect System QCS 2814 Instructions Underwriters Laboratories UL 348X Listed October 2016 78 0015 3160 3 A ...

Page 2: ... c Insulated 6 ground wire for entrance d Internal bottom mounted three point ground bar e Binding post log label f 3M Single Pair Test Probe 2827 g Lockable protective cover 1 2 3M Integrated Protection Terminal Dimensions Model Height Width Depth 4990IPT 100 13 330 mm 13 5 343 mm 6 152 mm 3M Indoor Outdoor Integrated Protection Terminal 4990IPT 100 pair 1 3 Protector Specifications Use only UL R...

Page 3: ...estors useless 2 2 Remove the outer door and open the splicing chamber by removing the chamber cover 2 3 In the upper right corner and lower right corner remove the 2 screws holding the front panel to the enclosure Remove the front panel assembly and set aside 2 4 Mount the terminal in the desired location utilizing the keyholes on the back of the enclosure 2 5 Route connector harness tails and gr...

Page 4: ...3 12 Use 3M Cable Ties or equivalent cable ties to secure the entrance cable to the base of the splice chamber 3 13 Route cable binders to appropriate block tails and splice per your company practice 3 14 Bundle splice conductors and place inside splice chamber 3 15 Replace splice chamber cover 4 0 Installing or Replacing the Electrical Protectors Note Use only UL Recognized 3M Single Pair Protect...

Page 5: ...ch firmly into place 5 3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways Cut jumper wires to appropriate length leaving at least 2 51 mm of slack 5 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 5 1 and 5 2 5 5 Terminate additional jumper wires by repeating the abo...

Page 6: ... 50 24 SC Harness XP Pair 1 50 with SC modules 80 6114 XXXX X 1 Communication Markets Division 6801 River Place Blvd Austin TX 78726 9000 Phone 1 800 426 8688 Web www 3M com Telecom Please recycle Printed in USA 3M 2016 All rights reserved 78 0015 3160 3 A 3M Scotchlok and MS2 are trademarks of 3M Company Important Notice All statements technical information and recommendations related to 3M s pro...

Reviews: