3.0  Feeder Cable Preparation, Strain  

 

Relief and Splicing

3.1  Feeder cable diameters for the 3M

 Integrated 

Protection Terminal 4990IPT:

Maximum Diameter

Entrance cable

1.25" (32 mm)

3.2  Remove entrance gasket in the bottom of the 

splice chamber.

3.3  Estimate size of cable diameter and slit gasket  

in X pattern.

3.4  Slide gasket down the cable past the point of 

sheath removal.

3.5  Place cable in temporary position to determine 

sheath opening location.

3.6  Allow minimum of 36" (914 mm) of cable beyond 

sheath opening location.

3.7  Remove sheath and install 3M

 Scotchlok

  

Shield Bond Connector, or equivalent, per 

company practice.

3.8  Place ground strap on the 3M Scotchlok Shield 

Bond Connector, or equivalent, post.

3.9  Install top nut on connector over strap and torque 

to 40 in.-lbs.

3.10  Locate cable tie loops at base of splice chamber 

and route 3M

 Cable Ties, or equivalent.

3.11  Route cable to splice chamber making sure  

gasket lines up and seals to bottom.

3.12  Use 3M Cable Ties, or equivalent cable ties,  

to secure the entrance cable to the base of the 

splice chamber.

3.13  Route cable binders to appropriate block tails  

and splice per your company practice.

3.14  Bundle splice conductors and place inside  

splice chamber.

3.15  Replace splice chamber cover.

4.0 Installing or Replacing the  

 

Electrical Protectors

Note: Use only UL Recognized 3M

 Single Pair Protectors 

2814SPG in the 3M terminals 4990IPTs.

Note: The 3M 2814SPD protectors must be mounted in 

a UL listed telephone protection enclosure or in 

the 3M Integrated Protection Terminals 4990IPT, 

4588IPT and 4588IPTN.

Note: The protectors shall be coordinated with NO. 26 

AWG or physically smaller fuse link wire.

Note: All protectors shall conform to installation  

requirements of the National Electric Code,  

ANSI/NFPA 70 (Article 800).

4.1 

The 3M 4990IPT terminals use only 3M Single 

Pair Protectors 2814 SPG.

4.2  The protectors must be installed in order to 

provide service.

4.3  Insert protectors into the 3M

 Quick Connect 

System (QCS) 2814 block with the block ground 

bar in place.

4.4  Raise cap on protector to connect jumper wire.

4

78-0015-3160-3-A

October 2016

Summary of Contents for 4990IPT

Page 1: ...tdoor Integrated Protection Terminals 4990IPT Indoor Outdoor Building Entrance Terminal with the 3M Quick Connect System QCS 2814 Instructions Underwriters Laboratories UL 348X Listed October 2016 78 0015 3160 3 A ...

Page 2: ... c Insulated 6 ground wire for entrance d Internal bottom mounted three point ground bar e Binding post log label f 3M Single Pair Test Probe 2827 g Lockable protective cover 1 2 3M Integrated Protection Terminal Dimensions Model Height Width Depth 4990IPT 100 13 330 mm 13 5 343 mm 6 152 mm 3M Indoor Outdoor Integrated Protection Terminal 4990IPT 100 pair 1 3 Protector Specifications Use only UL R...

Page 3: ...estors useless 2 2 Remove the outer door and open the splicing chamber by removing the chamber cover 2 3 In the upper right corner and lower right corner remove the 2 screws holding the front panel to the enclosure Remove the front panel assembly and set aside 2 4 Mount the terminal in the desired location utilizing the keyholes on the back of the enclosure 2 5 Route connector harness tails and gr...

Page 4: ...3 12 Use 3M Cable Ties or equivalent cable ties to secure the entrance cable to the base of the splice chamber 3 13 Route cable binders to appropriate block tails and splice per your company practice 3 14 Bundle splice conductors and place inside splice chamber 3 15 Replace splice chamber cover 4 0 Installing or Replacing the Electrical Protectors Note Use only UL Recognized 3M Single Pair Protect...

Page 5: ...ch firmly into place 5 3 Route the jumper wires to the distribution pair through wire loops on the block ends and through vertical and horizontal wireways Cut jumper wires to appropriate length leaving at least 2 51 mm of slack 5 4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 5 1 and 5 2 5 5 Terminate additional jumper wires by repeating the abo...

Page 6: ... 50 24 SC Harness XP Pair 1 50 with SC modules 80 6114 XXXX X 1 Communication Markets Division 6801 River Place Blvd Austin TX 78726 9000 Phone 1 800 426 8688 Web www 3M com Telecom Please recycle Printed in USA 3M 2016 All rights reserved 78 0015 3160 3 A 3M Scotchlok and MS2 are trademarks of 3M Company Important Notice All statements technical information and recommendations related to 3M s pro...

Reviews: