7
7.0
Jumper Installation
7.1
Make sure wires have clean-cut ends.
Bend the last 1/2" - 3/4" (13 mm - 19 mm) of wire 90
°
.
1/2" - 3/4"
(13 mm - 19 mm)
90
°
Hook
Bend Wire
7.3
With a screwdriver, rotate cap 90
°
clockwise.
Note:
Make sure screwdriver blade is fully inserted into cap slot
before rotating.
Note:
Ground special circuit jumper wire shields following
Ameritech practice AM 640-525-950, "Working at Cross-
Connect Cabinets - Standards for DS-1 Provisioning at
Cross-Connect Cabinets."
Note:
To remove jumper wire, rotate cap 90
°
counterclockwise.
90
°
7.2
Insert wire into port and through the cap until the wire is
visible from the exit port.
Insert Wire
Pair 25
Pair 21
TIP - left
Pair 1
RING - right
Pair 5
3" (76 mm)
slack each end
3" (76 mm)
slack each end
7.4
Split pair (TIP - left, RING - right) at assigned cap position. Always route jumper wires below the
connected cap.