6.0  Cable Port Seal

6.2

Scuff and round out the area of sheath where the
sealing tape and port will be located.

6.3

Slide the PST, (pull cord must be opposite 
the cabinet) the steel port and gasket over the 
cable and out of the Cabinet.

6.4

Wrap the sealing tape approximately 1" away 
from the Cabinet’s top or bottom, so it will 
center the cable in the port. Position and 
install the gasket and port to the Cabinet as 
shown in the drawing.

6.5

Build an even transition from the port 
to the cable with more sealing tape.

7.0 Cable Termination

7.1

Separate the Feeder and Distribution count of 
the cable(s) into 100 pair groups. Route the 
groups to the tie bars to the appropriate frame 
location according to frame count.

a.) It is recommended that the Feeder count is in
the center blocks and the Distribution count 
blocks are on the sides of the Feeder blocks in 
the Cabinet.

1

Distribution

451

Distribution

Distribution

450

Distribution

900

1-Feeder

451-Feeder

Feeder

900

Feeder

450

901

Distribution

1351

Distribution

Distribution

1350

Distribution

1800

3M

4295 FS 2700 Pair Cabinet

6.1

Two 3 3/8" and one 2 5/8" Metal Cable Ports are included with the Cabinet.  Use the appropriate sized 
port for the cable(s) in the Cabinet. An optional 4” Metal Cable Port can be ordered if needed. The Kits 
include a port, sealing tape and a collapsible tube called the 3M

Pull-N-Shrink Tube (PST).

6.6

Install the PST over the tape and port. Unwind the pull cord of the PST counter clockwise until the 
tube is collapsed and the core is removed.

6.7

Wrap entire PST with two half-lapped layers of 3M

88T Vinyl Tape or equivalent.

6.8

Secure the cable(s) to the Cable Tie Bar.

6.9  Attach the bond strap(s) to the Bond Plate and tie the strap(s) together and out of the way from the frame 

and jumper trough. Record the bond strap(s) identification on the Cable Bond Label in the Cabinet.

6.10  Reinstall the Cabinet’s Port Plate, the Top Center Frame Mount Bracket or the Bottom Jumper Wire 

Trough if removed.

3M

88T

Summary of Contents for 4295 FS

Page 1: ...4295 FS Pole Mount Cabinet Instructions June 2001 78 8130 5228 5 A ...

Page 2: ...able pairs of 3M 4220 Self Strip Termination Blocks can be loaded into the Cabinet The Blocks are preterminated with either 3M MS2 Modules or 3M 710 Connectors 1 2 Use of this cabinet for rehabilitation and expansion is covered in Section 9 0 of this instruction 1 3 Instructions for running jumpers installation of Priority Caps and the use of the included Test Probe are on the inside of the cabine...

Page 3: ...3 Test Probe with Holder 3 SS9KN Self Strip Blocks 900 Pair K Height Narrow Frames Cable Ground Bar Jumper Wireway Self Strip Block Assemblies 4295 FS Top Mount Bracket 4295 FS Bottom Mount Bracket ...

Page 4: ...Flanged Gland Kit 3 3 8 dia 3 11 4075 S or 4077 Series Sealant Boxes Test Probes 3 12 4327 Self Strip Single Pair Probe 3 13 4327 P Self Strip Pocket Probe 3 14 4328 Self Strip 25 Pair Test Connector 4 0 Cabinet Mounting 4 1 Attach the Top and Bottom Pole Mount Brackets according to the drawings The flat slotted edge of the Bottom Bracket is up Make sure that the Bottom Bracket is aligned and plum...

Page 5: ...ing the cable s in the cabinet An optional 4 Metal Cable Port can be ordered if needed 5 1 Open Cabinet doors loosen frame retaining screws and remove frames by lifting the bottom up and out of the cabinet 5 2 Cable Entry a For top entry cable s remove the Cabinet s Top Front Port Plate the Top Center Frame Mount Bracket and the Metal Port Covers s on the top of the Cabinet b For bottom entry cabl...

Page 6: ... Distribution Distribution 450 Distribution 900 1 Feeder 451 Feeder Feeder 900 Feeder 450 901 Distribution 1351 Distribution Distribution 1350 Distribution 1800 3M 4295 FS 2700 Pair Cabinet 6 1 Two 3 3 8 and one 2 5 8 Metal Cable Ports are included with the Cabinet Use the appropriate sized port for the cable s in the Cabinet An optional 4 Metal Cable Port can be ordered if needed The Kits include...

Page 7: ... 3M MS2 Modules always install the proper sized Sealant Box When using 3M MS2 Modules 3M 4075 or 4077 Series Sealant Boxes or 3M 710 Connectors containing sealants carefully follow safety health and environmental information on the label or the Material Safety Data Sheet 7 7 Secure the Frame in the upright position with the screw at the top of the Frame Repeat this procedure with the next two Fram...

Page 8: ...n You assume all risks and liability associated with such use Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture as of the date of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above...