3M 4295 FS Instructions Manual Download Page 1

4295 FS Pole Mount Cabinet

Instructions

June 2001
78-8130-5228-5-A

Summary of Contents for 4295 FS

Page 1: ...4295 FS Pole Mount Cabinet Instructions June 2001 78 8130 5228 5 A ...

Page 2: ...able pairs of 3M 4220 Self Strip Termination Blocks can be loaded into the Cabinet The Blocks are preterminated with either 3M MS2 Modules or 3M 710 Connectors 1 2 Use of this cabinet for rehabilitation and expansion is covered in Section 9 0 of this instruction 1 3 Instructions for running jumpers installation of Priority Caps and the use of the included Test Probe are on the inside of the cabine...

Page 3: ...3 Test Probe with Holder 3 SS9KN Self Strip Blocks 900 Pair K Height Narrow Frames Cable Ground Bar Jumper Wireway Self Strip Block Assemblies 4295 FS Top Mount Bracket 4295 FS Bottom Mount Bracket ...

Page 4: ...Flanged Gland Kit 3 3 8 dia 3 11 4075 S or 4077 Series Sealant Boxes Test Probes 3 12 4327 Self Strip Single Pair Probe 3 13 4327 P Self Strip Pocket Probe 3 14 4328 Self Strip 25 Pair Test Connector 4 0 Cabinet Mounting 4 1 Attach the Top and Bottom Pole Mount Brackets according to the drawings The flat slotted edge of the Bottom Bracket is up Make sure that the Bottom Bracket is aligned and plum...

Page 5: ...ing the cable s in the cabinet An optional 4 Metal Cable Port can be ordered if needed 5 1 Open Cabinet doors loosen frame retaining screws and remove frames by lifting the bottom up and out of the cabinet 5 2 Cable Entry a For top entry cable s remove the Cabinet s Top Front Port Plate the Top Center Frame Mount Bracket and the Metal Port Covers s on the top of the Cabinet b For bottom entry cabl...

Page 6: ... Distribution Distribution 450 Distribution 900 1 Feeder 451 Feeder Feeder 900 Feeder 450 901 Distribution 1351 Distribution Distribution 1350 Distribution 1800 3M 4295 FS 2700 Pair Cabinet 6 1 Two 3 3 8 and one 2 5 8 Metal Cable Ports are included with the Cabinet Use the appropriate sized port for the cable s in the Cabinet An optional 4 Metal Cable Port can be ordered if needed The Kits include...

Page 7: ... 3M MS2 Modules always install the proper sized Sealant Box When using 3M MS2 Modules 3M 4075 or 4077 Series Sealant Boxes or 3M 710 Connectors containing sealants carefully follow safety health and environmental information on the label or the Material Safety Data Sheet 7 7 Secure the Frame in the upright position with the screw at the top of the Frame Repeat this procedure with the next two Fram...

Page 8: ...n You assume all risks and liability associated with such use Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture as of the date of purchase 3M MAKES NO OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE If this product is defective within the warranty period stated above...