background image

Assembly schematic (see Figure 2) is based on suggested materials. 
Installation of this filtration system can be modified by using various adapters.

Parts and Materials Included:

1) Filter Head Assembly

2) Replacement Filter

Tools and Materials that may be Required (not included):

Gather the required tools before starting installation. 
Read and follow the instructions provided with any tools listed here.

A) Pipe Cutter

B) Two 1” NPT Male connectors

C) Three Ball Valves

D) PTFE Thread Tape

E) Adjustable Wrench

F) Torch (not shown)

G) Plumbing Solder (not shown)

H) Plumbing Flux (not shown)

I)  Common piping and fittings will be 
  required to complete the installation (not shown)

GETTING STARTED

City Water Installation

Well Water Installation

Master 

Shut-Off 

Valve

To Household 

Plumbing

Pump

Master 

Shut-Off 

Valve

To Household 

Plumbing

Pressure 

Tank

To reduce the risk associated with property damage due to water leakage:

  • Installation and Use 

MUST 

comply with all state and local plumbing codes.

CAUTION

0

 

0

 

0

 

0

 

6

 

9

Gallons

Gallons

2700

2700

3000

3000

Model

Model

BRP

BRP

20

20

10

10

30

30

40

40

50

50

70

70

80

80

90

90

0

Bad

Badger Meter

er Meter

300

300

600

600

1600

1600

1800

1800

1200

1200

2100

2100

2400

2400

Water 
Meter

Figure 1

2

1

A

B

C

D

E

• Professional Installation Required: 

Installation requires shutting water off to home, cutting home water sup-

ply pipe and using a welding torch to add piping and fittings.  Specialized tools and skills are required.  Not a 
do-it-yourself type of project.  Professional installation 

required

!

Summary of Contents for 3MPF201

Page 1: ...ure and free of leaks Shut off fuel or electric power supply to water heater after the water is shut off The disposable replacement filter MUST be replaced every 12 months at the rated capacity or sooner if a noticable reduction in flow rate occurs Read understand and follow all safety information contained in these instructions prior to installation and use of the 3MPF201 and 3MPF301 Series Filtr...

Page 2: ...n GETTING STARTED City Water Installation Well Water Installation Master Shut Off Valve To Household Plumbing Pump Master Shut Off Valve To Household Plumbing Pressure Tank To reduce the risk associated with property damage due to water leakage Installation and Use MUST comply with all state and local plumbing codes CAUTION 0 0 0 0 6 9 Gallons Gallons 2700 2700 3000 3000 Model Model BRP BRP 20 20 ...

Page 3: ...ad as shown Use common pipe and connections to assemble system 4 Use supplied bracket or pipe hangers to support the system 5 Install replacement filter into filter head by following replacement filter instructions as shown on next page 6 Open main water supply slowly to pressurize system and check for leaks 7 Close bypass valve and open faucet to flush no less than 10 gallons approximately 15 min...

Page 4: ...for one 1 year This warranty does not cover failures resulting from abuse misuse alteration or damage not caused by 3M Purification Inc or failure to follow installation and use instructions No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water condi tions and water consumption 3M PURIFICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EX...

Reviews: