13.10 Slide a segment of tubing over the fibers until it contacts the buffer
tube end. No more than twelve 250 µm fibers or four 900 µm
fibers should be placed into a tube.
13.11 Slide the segment of tubing over the buffer tube about 1" (25 mm)
and secure with two wraps of vinyl tape.
13.12 Mount the universal organizer adapter in the splice case base.
13.13 Cut the Dual-Lok to fit the four flat pads on the tray bottom.
Remove protective liner and adhere.