background image

(English) 

1

W   

 WARNING

This respirator helps protect against certain particles. 

Misuse may result in sickness or death

. For correct use, consult supervisor and 

these 

User Instructions,

 or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414.

IMPORTANT

Before use, wearer must read and understand these 

User Instructions

. Keep these instructions for reference.

Use For

Particles such as those from processing minerals, coal, iron ore, cotton, flour, and certain other substances. Liquid or oil based particles from sprays 

that do not also emit harmful vapors. Nuisance level organic vapor relief. (Nuisance level organic vapor refers to concentrations not exceeding OSHA 

PEL or applicable government occupational exposure limits, whichever is lower.) For additional information on 3M use recommendations for this class 

of respirator please consult the 3M Respirator Selection Guide found on the 3M Personal Safety Division (PSD) website at www.3M.com/workersafety 

or call 1-800-243-4630 in U.S.A. In Canada, call 1-800-267-4414.

Do Not Use For

Do not use for gases, asbestos or sandblasting; particulate concentrations that exceed either 10 times the occupational exposure limit or applicable 

government regulations, whichever is lower. Do not use for organic vapors, including those present in paint spraying operations, when concentrations 

exceed the US OSHA PEL or applicable government occupational exposure limits, whichever is lower. In the U.S., do not use when OSHA substance 

specific standards, such as those for arsenic, cadmium, lead in the construction industry, or 4,4’-methylene dianiline (MDA), specify other types of 

respiratory protection. This respirator does not supply oxygen.

Biological Particles

This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, 

Bacillus anthracis

Mycobacterium tuberculosis

etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe 

exposure limits for these contaminants.

Use Instructions

1.  Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can 

reduce respirator effectiveness and 

may result in sickness or death.

2.  Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the requirements of OSHA 29 

CFR 1910.134 such as training, fit testing, medical evaluation, and applicable OSHA substance specific standards. In Canada, CSA standard Z94.4 

requirements must be met and/or requirements of the applicable jurisdiction, as appropriate.

3.  The particles which can be dangerous to your health include those so small that you cannot see them.
4.  Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
5.  Store the respirator away from contaminated areas when not in use.
6.  Inspect each respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage 

including the two headbands, attachment points and noseclip. The respirator should be disposed of immediately upon observation of damaged or 

missing parts. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures 

around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered 

damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval.

7.  Dispose of used product in accordance with applicable regulations.

Use Limitations

1.  This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
2.  Do not use when particulate concentrations of contaminants are immediately dangerous to life and health, are unknown or exceed 10 times the 

permissible exposure limit (PEL) or according to specific OSHA standards or applicable government regulations, whichever is lower. Do not use 

when organic vapor concentrations exceed the OSHA PEL or other applicable exposure limits, whichever is lower.

3.  Do not alter, abuse or misuse this respirator.
4.  Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator.
5.  Respirators can help protect your lungs against certain airborne contaminants, however, they will not prevent entry through other routes such as 

the skin, which would require additional personal protective equipment (PPE).

6.  This respirator is designed for occupational/professional use by adults who are properly trained in their use and limitations. This respirator is not 

designed to be used by children.

7.  Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a physician and complete a medical evaluation 

prior to use.

8.  When stored in accordance with temperature and humidity conditions specified below, the product may be used until the “use by” date specified 

on the packaging.

Particulate Respirator R95

3

User Instructions

8247/07186

Summary of Contents for 07186

Page 1: ...concentrations not exceeding OSHA PEL or applicable government occupational exposure limits whichever is lower Recommandé par 3M pour la protection contre les concentrations nuisibles de vapeurs organiques Par concentrations nuisibles de vapeurs organiques on entend les concentrations inférieures à la limite d exposition admissible de l Occupational Safety and Health Administration OSHA des États ...

Page 2: ...tion and applicable OSHA substance specific standards In Canada CSA standard Z94 4 requirements must be met and or requirements of the applicable jurisdiction as appropriate 3 The particles which can be dangerous to your health include those so small that you cannot see them 4 Leave the contaminated area immediately and contact supervisor if dizziness irritation or other distress occurs 5 Store th...

Page 3: ...RENSEIGNEMENTS SUPPLÉMENTAIRES Aux États Unis Internet www 3m com workersafety Assistance technique 1 800 243 4630 Autres produits 3M 1 800 364 3577 ou 1 651 737 6501 Fig 1 Fig 2 Fig 3 Fig 4 Fitting Instructions Must be followed each time respirator is worn 1 Cup the respirator in your hand with the nosepiece at your fingertips allowing the headbands to hang freely below your hand Fig 1 2 Position...

Page 4: ...an 19 5 percent oxygen B Not for use in atmospheres immediately dangerous to life or health C Do not exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never sub...

Page 5: ...taires pour ces contaminants Directives d utilisation 1 Tout manquement aux directives et aux restrictions relatives à l utilisation de ce respirateur pendant la durée complète de l exposition peut en diminuer l efficacité et peut provoquer des problèmes de santé ou la mort 2 Avant d utiliser ce respirateur en milieu professionnel mettre sur pied un programme de protection respiratoire écrit confo...

Page 6: ...rviseur Fin de la durée de conservation Utiliser le respirateur avant la date de péremption indiquée sur l emballage 86 F 30 C 4 F 20 C Plage de températures d entreposage 20 à 30 C 4 à 86 F 80 Humidité relative maximale pour l entreposage 80 H R Durées maximales d utilisation 1 Quitter la zone contaminée immédiatement et remplacer le respirateur s il est endommagé encrassé ou si la respiration de...

Page 7: ...ERTISSEMENTS ET RESTRICTIONS A Ne pas utiliser lorsque la concentration ambiante en oxygène est inférieure à 19 5 B Ne pas utiliser si l atmosphère présente un danger immédiat pour la vie ou la santé C Ne pas utiliser en présence de concentrations supérieures au taux établi par la réglementation J L utilisation et l entretien inadéquats de ce produit peuvent provoquer des blessures ou la mort M To...

Page 8: ...del uso ocupacional de este respirador debe implantarse un programa escrito de protección respiratoria que cumpla con todos los requisitos de OSHA 29 CFR 1910 134 como capacitación prueba de ajuste evaluación médica y las normas de específicas aplicables de OSHA para cada sustancia En Canadá se debe cumplir los requerimientos de la norma CSA Z94 4 o los requerimientos legales aplicables según corr...

Page 9: ...tes de la fecha usar hasta especificada en el empaque 86 F 30 C 4 F 20 C Rango de temperatura de almacenamiento 20 C 4 F a 30 C 86 F 80 Humedad relativa máxima de almacenamiento 80 HR Limitaciones de tiempo de uso 1 Si el respirador se daña ensucia o se dificulta la respiración a través de él salga inmediatamente del área contaminada y reemplace el respirador 2 Si hay aerosoles de aceite en el amb...

Page 10: ...ncia de filtración contra aerosoles de sólidos y líquidos entre otros los que contienen aceite 3M ST PAUL MINNESOTA USA 1 800 243 4630 THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATION RESPIRATOR TC PROTECTION1 CAUTIONS AND LIMITATIONS2 84A 1350 R95 X ABCJMNOP 1 PROTECTION R95 Particulate Filter 95 filter efficiency level effective against all particulate aerosols time use restrictio...