Research & Development
Default:
100 (1 second)
12.2.4 Line status query
Description:
Query the line status
Command:
AT%I0
Parameter:
None
Response:
<Event>
0 – Line de-attached, nothing happens.
1 - Line voltage difference / absolute value is below the threshold defined in
F-2.2.
2 - Line voltage difference / absolute value is over the threshold defined in 2.2.
3 - Line current difference / absolute value is below the threshold defined in 2.2
(Note: when set S59=32, Modem will put 3 chars 47 47 47 to alert extra.
otherwise you can disable it by set S59 = 0)
4 - Line current difference / absolute value is over the threshold defined in 2.2
OK
12.2.5 RJ11 status query
Description:
Query the RJ11 status
Command:
AT%I1
Parameter:
None
Response:
<Line status>
0 - No phone line is attached.
1 – A phone line is attached.
OK
12.2.6 Voltage/Current value query
Description:
Query the voltage/current value, and the value type, absolute or
differential, depends on the detection mode you set.
Command:
AT%I2
Parameter:
None
Response:
<Value>
.
This value is an unsigned value, and please refers to Table12.2.1 /
Table12.2.2 for this value.
OK
Page
44
of
50
Revision 1.0
2003/6 From 3JTech