background image

2× Panel

gauge min.* 

*Varia Only. For other
  materials see spec sheets

Hardware shown in this document is for interior use only.

Overview

Panel Caps

Material recommendations

Do not

 use cyanoacrylate or solvent type thread locking materials with 

Varia

.

3form materials must be separated from metal at all times, especially threads. 1" diameter caps ship bundled with press-fit
washers which press into a 5/8" diameter hole to stay in place during the installation process to protect the panel from any metal 
contact. 3/4" diameter caps (3-15-0020-K) are meant only for 

Varia

 and cannot be used with other materials.

3-15-17

0

5 Pressure Fit Washer ships together

                   with 1" dia. caps

3form 

Varia

 and 

Monolithic Glass

 must be protected from metal at all times, refer to the next page for Instructions. See 

Versa 

Glass Integrator Solution Document

 for more information on glass.

Part Number

Notes

3-15-0020-K

3-15-0025-K

use press fit washers as

described next page

use provided washer front and 

back of panel

3-15-0026-K

3-15-0027-K

use press fit washers as

described next page

use press fit washers as

described next page

3-15-0028-K

use press fit washers as

described next page

Thread Size

(3/4") 20mm � (3/4") 20mm

M8 Thread

(1") 25mm � (3/4") 20mm

M8 Thread

(1") 25mm � (11/16") 17mm

M8 Thread

(1") 25mm � (3/8") 10mm

M8 Thread

(1") 25mm � (1") 25mm

 M8 Thread

Hole Size to Drill

1/2"

5/8"

5/8"

5/8"

5/8"

3-15-0029-K

use press fit washers as

described next page

3-15-1716-K

3-15-1717-K

use press fit washers as

described next page

use press fit washers as

described next page

3-15-1719-K

use press fit washers as

described next page

(1") 25mm � (1-1/4") 32mm

M8 Thread

(1") 25mm 2-part cap for thinner 

material M8 Thread

(1") 25mm 2-part cap for thinner 

material M8 Thread

(1") 25mm 2-part cap for thinner 

material M8 Thread

5/8"

5/8"

5/8"

5/8"

3-15-1720-K

use press fit washers as

described next page

(1") 25mm 2-part cap for thinner 

material M8 Thread

5/8"

For more information, please visit 3-form.com or call 800.726.0126

AUG 2019 | MAN-004 Versa | REV 017 © 2018 3form, Inc. All rights reserved.

Versa

tm

Solution Document/Installation Manual

6

Summary of Contents for Versa Series

Page 1: ... work with 3form materials Using this Installation Manual because there are many components and possibilities with 3form Versa hardware this manual is organized by individual component installation Please see pages 29 33 for different installation components and applications and follow the corresponding page to find instructions for that particular element of the installation For more information ...

Page 2: ...1 Mitered Corner Splice 42 Drop Ceilings 43 Extrusion Slot Covers 44 Side Bracket Attachment 45 Shelving and Spider Attachment 46 Panel Size and Gauge Attachment Chart 48 Flat Spider Attachment 49 Door Hinges 50 Door Catch 51 Door Latch 52 Slim Profile Connection 53 Versa System Overview 1 Versa Solutions 10 Installation 29 General Specifications 54 For more information please visit 3 form com or ...

Page 3: ... in max 10 0 length Longer available by request 60mm 60mm Square Available in max 10 0 length Longer available by request 32mm 37 5mm Slim One Available in max 10 0 length 32mm 40mm Slim Two Available in max 10 0 length 40mm 40mm Slim Four Available in max 10 0 length 35mm 90mm Beam Available in max 14 0 length Longer available by request Material is supported in all Versa applications using eithe...

Page 4: ...ure fit assemble at the ceiling rotating base at floor or substandard substrate anchorate will create conditions where additional deflection can be anticipated Floor to Ceiling Condition 10 5 0 1 32 5 16 1 8 Blade 10 5 0 1 32 5 16 1 8 Beam 10 0 3 8 1 32 3 32 1 4 Square 10 0 3 8 1 32 3 32 1 4 Block 8 0 5 32 1 32 3 8 Oval 8 0 5 32 1 32 3 8 Bar 5 2 1 16 Slim Four 5 4 1 16 Slim Two 3 32 4 4 Slim One 4...

Page 5: ...ing base at floor or substandard substrate anchorate will create conditions where additional deflection can be anticipated Cantilever Condition 3 8 3 8 3 8 3 16 3 8 3 16 5 16 5 16 6 0 5 0 8 0 0 0 1 16 1 32 Blade 8 0 0 0 1 16 1 32 Beam 4 9 5 32 0 0 1 16 Square 4 9 5 32 0 0 1 16 Block 4 0 1 32 0 1 4 3 32 Oval 4 0 1 32 0 3 32 1 4 Bar 3 1 0 1 32 3 16 Slim Four 3 2 0 1 32 5 32 Slim Two 0 1 16 2 7 Slim ...

Page 6: ...ommended material types and gauges for each solution Accessories This system offers all the components you will need to create installations in the following categories Applications Partitions Dividers Doors Shelving For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Solution Document Installation Manual 4 ...

Page 7: ...inst the ceiling The top adjustable plate can be attached to the ceiling with screws or can simply be secured with pressure using the barrel nut fig 2 3 The maximum extension of the threaded rod should be 6 please account for this when determining the profile lengths Pressure Fit Assembly Overview Fig 1 Fig 3 Fig 2 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 ...

Page 8: ...ibed next page use provided washer front and back of panel 3 15 0026 K 3 15 0027 K use press fit washers as described next page use press fit washers as described next page 3 15 0028 K use press fit washers as described next page Thread Size 3 4 20mm 3 4 20mm M8 Thread 1 25mm 3 4 20mm M8 Thread 1 25mm 11 16 17mm M8 Thread 1 25mm 3 8 10mm M8 Thread 1 25mm 1 25mm M8 Thread Hole Size to Drill 1 2 5 8...

Page 9: ... and Thicker Materials 3 16 and Thinner 2 Piece Cap For Thicker and Thinner Panels 1 Install hardware at substrate and M8 Threaded rod into substrate hardware barrel or other so it is ready to receive cap and panel For thinner panels place recessed white bushing onto threaded rod in preparation for panel installation 2 Press fit washers into 5 8 diameter hole If drilled properly the washers should...

Page 10: ... 3 15 0027 1 8 25mm 1 Cap w 17mm threaded rod 3 15 0026 Designed for Varia Chroma Struttura Stone Pressed Glass 100 Designed For Varia 100 Designed for Varia 100 Designed for Varia Struttura 100 Summary 1 Piece Cap Chart Another integral part of the Versa system regardless of application is the 1 piece threaded cap The length of threading needs to be chosen based on the gauge of material To select...

Page 11: ... 3 15 1721 K 3 15 1758 Designed for Varia Chroma Struttura Stone 100 Designed for Varia 100 Designed for Varia Chroma Struttura Stone 100 1 16 3 16 3 8 3 4 1 1 2 1 8 1 4 Summary 2 Pieces Cap Chart Another integral part of the Versa system regardless of application is the 2 piece cap The length of rod needs to be chosen based on the gauge of material This threaded rod is then capped using your choi...

Page 12: ...al Plate Cover 3 15 1745 K 5 Square Plate Cover 3 15 1746 K 6 Oval Plate Cover 3 15 0714 K 6 Square Plate Cover 3 15 0715 K Slim Plate Cover 3 15 1747 K 3 15 0707 K 3 15 0712 K Pivot Base 3 15 1744 K Pressure Fit Assembly 3 15 0804 K Sleeve 3 15 1741 Standoff Cap and Panel Protection 2 Piece Bracket 3 15 1752 K 16mm Duo Bracket 3 15 5001 K 5 Two Part Bottom Plate for Concrete 3 15 6500 KC 6 for Wo...

Page 13: ...using the Floor Plate Cover For temporary installations this pressure fit system does not need to be bolted to the ceiling or floor or for a more permanent and secure installation the top and bottom plates may be bolted to the ceiling and floor Blade 3 Beam 3 or 1 Sleeve 3 15 1741 8 Slot Cover 3 15 1732 3 3 3 Bottom Plate 3 15 1736 K 5 Two Part Bottom Plate for Concrete Requires Cover Plate 3 15 6...

Page 14: ...fit system can be installed using different profiles In this example where the goal is to have panels placed above other panels spiders are being used with 2 piece caps instead of side brackets This allows you to conceal the profiles behind the material and have as many different types of panels as desired 4 point 2 point and 1 point spiders are available to add flexibility and ease of installatio...

Page 15: ...e partitions can turn to the closed position to create a separate part of a room or can be opened for full use of the room It is recommended that the maximum width of pivoting partitions is 38 each For thicker gauges you will need more Spiders to support additional weight The recommended height of the partitions is dependent on the Versa Profile used refer to the chart on page 2 for more informati...

Page 16: ...ilever 72 3 15 1941 K 6 Base Plate for Wood 3 15 0713 KW 5 Blade Plate Cover 3 15 1733 K 6 Blade Plate Cover 3 15 1940 K 6 Beam Plate Cover 3 15 1939 K 5 Square Plate Cover 3 15 1746 K 6 Square Plate Cover 3 15 0715 K 5 Oval Plate Cover 3 15 1745 K 6 Oval Plate Cover 3 15 0714 K Slim One Plate Cover 3 15 1747 K Slim Two Plate Cover 3 15 0707 K Slim Four Plate Cover 3 15 1800 K Square Base Plate 3 ...

Page 17: ...rming Caps cover the tops of the profiles and Slot Covers conceal the exposed slots to create a very clean look as the Side Brackets hold the material between the profiles It is recommended that these free standing partitions be no taller than 4 3 8 2 Piece Bracket 3 15 0829 Slot Cover 3 15 1732 Oval 3 15 0790 K Bar or Free Standing Base 3 15 0803 K Bar Top Cap 3 15 0141 K Oval Cap 3 15 0788 K or ...

Page 18: ... and Varia panel size is 48 wide 93 high Maximum glass size is 48 wide 72 high See Versa Glass Integrator Solution Document for more information on glass Slot Cover 3 15 1732 Foot For Partition 3 15 0874 K Slim One Blade Beam or 2 Piece Bracket 3 15 1752 K Slim Post Mount 3 15 1731 K Blade Cap 3 15 1728 K Beam Top Cap 3 15 0139 K or For more information please visit 3 form com or call 800 726 0126...

Page 19: ... 0131 Oval 0 60 0107 Blade 0 60 0120 Slim 2 0 60 0103 Slim 1 0 60 0135 Bar 0 60 0135 Oval 0 60 0107 Block 0 60 0131 Square 0 60 0109 Beam 0 60 0127 Solution 2 Versa Compatibility Chart for Free Standing Dividers For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Solution Document Installation Manual 17 ...

Page 20: ...rmation 2 3 3 3 3 3 3 Slot Cover 3 15 1732 5 Bottom Plate 3 15 1736 K 5 Two Part Base Plate for Concrete Requires Cover Plate 3 15 6500 KC or or Square Base Plate 3 15 6502 K 6 Two Part Base Plate for Cantilever 72 3 15 1941 K or Blade Beam or 40 3 3 3 3 3 3 20 M8 T Nut 3 15 0826 Standoff Cap 20 2 leg 3D Spider 3 15 1735 K 5 Blade Plate Cover 3 15 1733 K Beam Plate Cover 3 15 0136 K 6 Beam Plate C...

Page 21: ...over 3 15 0715 K 6 Oval Plate Cover 3 15 0714 K 5 Two Part Bottom Plate For Concrete 3 15 6500 KC 6 For Wood 3 15 0713 KW Bottom Plate 3 15 1736 K Square Base Plate 3 15 6502 K Pressure Fit Assembly 3 15 0804 K Oval Cap 3 15 0788 K Square Cap 3 15 1537 K Blade Cap 3 15 1728 K Doors Bar Plate Cover 3 15 0138 K Block Plate Cover 3 15 0137 K Beam Plate Cover 3 15 0136 K Bar Top Cap 3 15 0141 K Block ...

Page 22: ...e Floor Plate Cover conceals the screws on the Floor Plate creating a clean simple partition system It is recommended that doors be no more than 36 wide otherwise the doors will be too flexible Note Versa Hinge and Latch Panel must be used with 1 2 gauge Varia Slot Cover 3 15 1732 4 or Blade Beam 2 2 or or Bottom Plate 3 15 1736 K 5 Two Part Bottom Plate for Concrete Requires Cover Plate 3 15 6500...

Page 23: ... 3 15 0701 M5 Snaptoggle 1 3 15 0079 M5 CSK 50mm 45 Bracket 3 15 1526 3 8 Side Bracket 3 15 0787 3 4 Side Bracket 3 15 1540 Solution 3 Wall Plate Adapter Anchoring Matrix 1 Notes M5 Snaptoggle for 3 8 drywall estimated to be half of 1 2 drywall value for 3 16 thread 120 lbs for ultimate tensile and 125 lbs for ultimate shear Safety factor of 4 suggested 30 lbs tensile and 31 lbs for shear M6 Snapt...

Page 24: ...Head 50mmL 1 3 15 0700 M6 Snaptoggle 1 3 15 0702 M6 Button Head 50mmL 1 3 15 0762 M6 Rampa Screw 1 M6 Button Head 12mmL comes with 3 15 1752 1 3 15 0701 M5 Snaptoggle 1 3 15 0079 M5 CSK 50mm 1 3 15 0701 M5 Snaptoggle 1 3 15 0079 M5 CSK 50mm 1 3 15 0700 M6 Snaptoggle 1 3 15 0703 M6 Standard Head Screw 50mm 1 3 15 0701 M5 Snaptoggle 1 3 15 0079 M5 CSK 50MM 1 3 15 0701 M5 Snaptoggle 1 3 15 0079 M5 CS...

Page 25: ... 15 0707 k Slim Four End Cap 3 15 1800 Slim Four Plate Cover 3 15 0712 k Slim One Slim Two Slim Four 3 8 Side Bracket 3 15 0787 K M8 T Nut 3 15 0826 Solution 4 Pony Wall For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Solution Document Installation Manual 23 ...

Page 26: ...nel without requiring hole fabrication 1 16 32 1 1 Slim Two End Cap 3 15 0708 M8 T Nut 3 15 0826 3 8 Side Bracket 3 15 0787 K Slim Two Slim Two Plate Cover 3 15 0707 K Slim One End Cap 3 15 5555 3 Slim One 3 Slim One Plate Cover 3 15 1747 K 3 Slim Bottom Plate 3 15 0705 K 5 Slim Four Cover Plate 3 15 0712 K 1 Slim Four 1 Slot Cover 3 15 1732 1 Slim Four End Cap 3 15 1800 1 For more information ple...

Page 27: ...re Plate Cover 3 15 1746 K 5 Oval Plate Cover 3 15 1745 K Slim Plate Cover 3 15 1747 K Square Base Plate 3 15 6502 K Standoff Cap and Panel Protection Slot Cover 3 15 1732 Sleeve 3 15 1741 2 leg 3D Spider 3 15 1735 K Slim Post Mount 3 15 1731 K Bar Plate Cover 3 15 0138 K Block Plate Cover 3 15 0137 K Beam Plate Cover 3 15 0136 K See pages 6 to 9 For more information please visit 3 form com or cal...

Page 28: ...2 2 2 Square Base Plate 3 15 6502 K or or 8 2 2 4 4 2 2 16 Clear Standoff for Spider Shelving 3 15 1727 2 leg 3D Spider 3 15 1735 K Bar Plate Cover 3 15 0138 K Oval Plate Cover 3 15 1745 K or Oval 3 15 0790 K Bar or Oval Plate Cover 3 15 1745 K Bar Plate Cover 3 15 0138 K or See pages 6 to 9 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form...

Page 29: ...elving 3 15 1727 2 leg 3D Spider 3 15 1735 K Sleeve 3 15 1741 3 M8 T Nut 3 15 0826 52 2 Piece Bracket 3 15 1752 K 8 12 Pressure Fit Assembly 3 15 0804 K 3 24 Slot Cover 3 15 1732 8 Slim One 6 Solution 5 Shelving Example 2 Versa Shelving 2 See pages 6 to 9 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Sol...

Page 30: ...ofile Oval Square Blade Slim Post Mount 3 15 1731 K Slim One 1 2 Clear Standoff for Spider Shelving 3 15 1727 2 leg 3D Spider 3 15 1735 K Cap or 2 Pieces Cap 3 6 6 See pages 6 to 9 4 Versa Profile Oval Square Blade Slim Post Mount 3 15 1731 K Slim One 2 4 Clear Standoff for Spider Shelving 3 15 1727 2 leg 3D Spider 3 15 1735 K Cap or 2 Pieces Cap 6 12 12 See pages 6 to 9 For more information pleas...

Page 31: ...installation Please see pages 29 to 33 for different installation components and applications and follow the corresponding page to find instructions for that particular element of the installation Page 37 Page 46 Page 49 Page 34 Page 35 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 29...

Page 32: ... Drop Ceiling Hinged Door Page 34 Page 35 Page 51 Page 45 Page 43 Page 52 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 30 ...

Page 33: ...tanding Partition Page 38 Page 39 Page 40 Page 39 Page 40 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 31 ...

Page 34: ...g Page 46 Page 44 Page 42 Page 34 Page 35 Page 34 Page 35 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 32 ...

Page 35: ...e scenarios Floor To Ceiling Bolted Post Floor To Ceiling Pressure Fit Post Floor To Wall Bolted Post Floor To Ceiling Pivot Post Free Standing Post Page 34 Page 35 Page 34 Page 35 Page 34 Page 35 Page 34 Page 35 Page 34 Page 35 Page 37 Page 42 Page 37 Page 38 Page 39 Page 41 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights ...

Page 36: ...d anchors for the floor substrate which should be supplied by the installer Attach bottom plate with attached post to the floor Attach bottom plate to the post using 4 12 self tapping screws 3 15 0869 These self tapping screws require a 3 square drive bit for installation For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights rese...

Page 37: ...ctions that ship on 3form Technical Specs and Downloads also ships with hardware for drilling and inserting Flush Anchors into concrete Install cover plate prior to attaching aluminum portion of 2 Part Baseplate to Versa Post using provided 12 self tapping screws 3 15 0869 These self tapping screws require a 3 square drive bit for installation HILTI 3a For cantilever installations above 72 only On...

Page 38: ...s drop cover over assembly 6 2 Part Baseplate for wood 3 15 0713 KW Fasten post assembly to prior installed steel part base plate using provided M8 countersunk screws drop cover over assembly Installation 2 Part Base Plate with Cover For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 36 ...

Page 39: ... in the barrel nut Measure the distance from the top of the post to the receiving nut portion of the Top Pressure Fit Plate Then use an appropriate saw for cutting aluminum to cut the Pressure Fit Sleeve to this same length Then simply snap the 2 sides of the Pressure Fit Sleeve over the barrel nut and Top Pressure Fit Plate If the fit of the Pressure Fit Sleeve is too tight to snap together by ha...

Page 40: ...by using provided 12 self tapping screws 3 15 0869 These self tapping screws require a 3 square drive bit for installation For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 38 ...

Page 41: ...ding base These self tapping screws require a 3 square drive bit for installation to the free standing base Installation Free Standing Foot 1 2 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 39 ...

Page 42: ...Foot 1 2 Installation Versa Profile Perpendicular Attachment 1 2 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 40 ...

Page 43: ...rt the set screw so the threaded rod won t turn Then place the included washers over the threaded rod and place the hollow section of the post over the threaded rod The post should turn and the threaded rod should not This installation should be duplicated on the ceiling using the same washers For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3fo...

Page 44: ...to cut the post to a 45 degree angle 3 A Corner Splice should be used on each side of the post Tightly insert the Corner Splice into each side of the post and set it in place using 4 set screws for each Corner Splice For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 42 ...

Page 45: ...the Pressure Fit Assembly instructions on page 37 Cut out a section of the ceiling tile appropriate for the size of the post you are using but not to exceed 4 in diameter For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 4 3 ...

Page 46: ...Installation Versa Slot Cover 1 2 3 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 4 4 ...

Page 47: ...the bushings are in the appropriate order with the panel and use the countersunk screws to attach the back side of the bracket through the panel and into the front side of the bracket For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 4 5 ...

Page 48: ...de the Spider into position then tighten down the screw Decide which part of the 3D Spider you want to receive the threaded rod Then using all of the appropriate bushings that came with the 2 Piece Cap see pages 9 and 47 attach the panel to the 3D Spider For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Inst...

Page 49: ...hing configurations that come with the 2 Piece Caps You can find specific detail on the parts to order in the Versa Solutions Document Please also see page 9 for the attachment requirements for different sizes and gauges of panels Please use all of the appropriate bushings and washers and the appropriate number of attachment points for your installation Follow the illustrations below for the appro...

Page 50: ...d Gauge Attachment Chart 4 10 4 8 4 6 4 4 3 3 2 2 1 3 16 2 8 3 6 For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 48 ...

Page 51: ...Nut Thread the screw into the T Nut without completely tightening it Slide the Spider into position then tighten down the screw Also if you need to keep the Spider from turning in the post you can use the provided screw to put into the back of the Spider which will go into the slot and keep the Spider from turning 1 2b 2c 2d 2a For more information please visit 3 form com or call 800 726 0126 AUG ...

Page 52: ...et through the panel and into the front side of the bracket Repeat this step for all brackets in the hinged door Slide the entire door into position then tighten down all screws For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 50 ...

Page 53: ...the Door Catch into the T Nuts Thread the screws into the T Nuts without completely tightening them Then line up the opening in the Door Catch with the Door Latch on the door and tighten the screws For more information please visit 3 form com or call 800 726 0126 AUG 2019 MAN 004 Versa REV 017 2018 3form Inc All rights reserved Versa tm Installation Manual 51 ...

Page 54: ...the door closed and latch it from that side rather than pulling the door closed toward you If you desire the door to be pulled into the closed position from the latching side of the door you will need to disassemble the lock and flip the innermost plastic block 180 degrees as shown above then reassemble the lock in this fashion Assemble the lock onto the panel using the 2 countersunk screws provid...

Page 55: ... 15 0869 These self tapping screws require a 3 square drive bit for installation Attach the Profile Connector to the Versa Post by sliding the T Nuts into the exposed slot and inserting the countersunk screws through the Profile Connector into the T Nuts Once the Slim Profile is in its desired location tighten the screws For more information please visit 3 form com or call 800 726 0126 AUG 2019 MA...

Page 56: ... 0768 3 15 0781 3 15 0848 K 3 15 0787 K 3 15 0830 K 3 15 0831 K 3 15 1501 K 3 15 1521 K 3 15 1526 K 3 15 1540 K 3 15 1728 K 3 15 1731 K 3 15 1733 K 3 15 1736 K 3 15 1737 K 3 15 1744 K 3 15 1738 3 15 1752 K 3 15 5555 Die Cast Aluminum Aluminum Extrusions Milled Aluminum NA Interior Only Satin Clear Anodize Powdercoating Available Aluminum 5052 H32 or H34 3 15 0788 K 3 15 1537 K 3 15 1745 K 3 15 174...

Page 57: ...09 these facilities consumed nearly 208 million pounds of recycled aluminum Approximately 14 of the total rep resented post consumer material with the remainder post industrial scrap from Hydro s extrusion facilities our custom ers and other extruders In 2009 the scrap content of 6000 series alloy billet produced in the EA casthouses and consumed in the EA extrusion facilities exceeded 70 as it di...

Reviews: