CUSTOMER SUPPLIED EQUIPMENT
The equipment listed below is not part of the ProX DMP100 system however
all of the equipment listed is required
. The
customer can purchase this equipment from an independent source or from 3D Systems (if so indicated).
•
Vacuum Cleaner - Can be purchased from 3D Systems
•
Oxygen Monitor - Can be purchased from 3D Systems
•
Dust collection system
Vacuum Cleaner
Supplied by
: Customer or 3D Systems
Installed by
: Customer
Installations must have a wet separator, explosion proof vacuum cleaner certified for minimum ATEX
zone 22 (Europe), or Class II, Division II (USA). The RUWAC, NA35 serie explosion proof vacuum is
recommended.
Oxygen Monitor
Supplied by
: Customer or 3D Systems
Installed by
: 3D Systems
For safety when working with argon, you must install a room area oxygen monitor on the wall of your ProX DMP100 room. The
oxygen monitor should be installed approximately 60 cm (24 inches) above the floor.
The models offered by 3D Systems are:
•
Oxygen Room Monitor, 120V (P/N
23746-101-01)
•
Oxygen Room Monitor, 220V, Universal Plugs (P/N 23746-101-02)
Dust Collection System
Supplied by
: Customer
Installed by
: Customer
3D Systems recommends a whole room, dust collection system to remove airborne particles out of
the air any time metal powder is handled.
A portable dust collection system is required to be able to manipulate and focus the dust collection
nozzle anywhere it’s needed.