FACILITY REQUIREMENTS POSTER
Control Cabinet
power panel
• 230 VAC
• 50/60 Hz
• 5 kVA
• 1ph + PE
A/C
Air Conditioning
• required
•
do not install vent directly above process station
Gas
Bulk gas tank
▪
Nitrogen : 99.99% pure nitrogen
▪ Argon : Quality 4.8
Gas cylinders
▪ Nitrogen : 99.99% pure nitrogen
▪ Argon : Quality 4.8
▪ Connect cylinders with auto-switching
manifold to ensure constant gas
supply during build
1
2
Compressed Air
min 15° C (59° F)
30° C (86° F)
max
Room temperature
setpoint and stability
• set temperature between 20° C and 25° C
(
68° F and 77° F)
• temperature should be constant to ±5
° C
(± 9° F)
Atmosphere
Note : the painting pipe colors are only for indication, and might not fit with your local, state and federal regulations.
Always refer to the pipe color coding standards of your local, state and federal regulations.
Room oxygen monitor
• recommended
• customer supplied/installed
• safety interlock contact rating: 10 A
Compressed Air
• customer supplied/installed
Network connection
• recommended
Inert gas
• customer supplied/installed
Gas
ProX DMP100
Connection Type
Quick coupler plug, internal diameter 6mm
Flow Rate
Manufacturing : 5 - 10 L/min
(
0.17 - 0.35 cubic feet per minute)
Purge : 30 L/min (
1.06 cubic feet per minute)
Supply Pressure
Minimum 5.5 bar (80 psi) - Maximum 6.9 bar (100 psi)
Quality
Nitrogen : 99.99%
Argon : 4.8 or better
Compressed air
ProX DMP100
Connection Type
Quick coupler plug, internal diameter 6mm
Flow Rate
10 L/min (0.35 cubic feet per minute)
Supply Pressure
Minimum 6 bar (87 psi) - Maximum 8 bar (116 psi)
Quality
Class 4,4,4 according to ISO 8573-1:2010