3D Systems ProX DMP 100 Original Instructions Manual Download Page 11

8

3D SYSTEMS, INC

.

5

  ATMOSPHERE REQUIREMENTS

ROOM VENTILATION

The DMP process takes place in an inert atmosphere inside the process chamber (Nitrogen or Argon, depending on material 

used). During the preparation and building process, the gas is released into the work place. Therefore, in small rooms, a 

minimum ventilation is required.
During loading and unloading the machine, powder particles will become airborne. The presence of metal powder in the work 

environment is unsafe and must be avoided as much as possible. Therefore adequate room ventilation (50 cubic meters/hour) 

is recommended and it is strongly advised to wear PPE (Personal Protective Equipment). 

Room Air Source

The facility HVAC system provides 

source air only

.  Air that is introduced into the room is not allowed to recirculate back into 

the facility HVAC system.

The atmosphere in the ProX

® 

DMP100 installation room must meet the following specifications:

ATMOSPHERIC VARIABLES

REQUIREMENTS

Room temperature

Heating and air conditioning installed

A/C not blowing directly onto the main cabinet

Temperature

Operating range: (15 to 30) °C; (59 to 86) °F
Storage range: (5 to 50) °C; (41 to 122) °F

Non-condensing relative humidity

No higher than 70%

Room air changes

4 per hour minimum

Heat dissipation

Maximum:     1 kW ( 3 412 BTU/hr)

Average:   0.75 kW ( 2 559 BTU/hr)

Atmospheric corrosives

None; Clean Dry Air (CDA) is required

Room Air Exhaust

The facility must have a separate system for removing the air from the room.  The system must remove the room air directly 

to the outside.  For the exhaust system, 3D Systems recommends the use of TEFC (Totally Enclosed Fan-Cooled) motors for this 

application.

  WARNING: FAILURE TO EXHAUST THE ROOM AIR DIRECTLY TO THE OUTSIDE WILL PUT PERSONNEL AT RISK  

 

FOR BREATHING AIR CONTAMINATED WITH METAL PARTICLES AND WILL PUT THE FACILITY AT RISK FOR AUTO- 

 

IGNITING FIRES .

 

WARNING: IF YOU ARE USING REACTIVE METALS, (TITANIUM OR ALUMINUM) AIR EXTRACTION EQUIPMENT  

  SHOULD NOT CONTAIN FILTERS . FINE METAL PARTICLES WILL BE COLLECTED BY THE FILTER AND WILL BE A  

 

SOURCE OF AUTO-IGNITING FIRES .

Summary of Contents for ProX DMP 100

Page 1: ...D Production Printer Facility Requirements Guide Original Instructions Please refer back to http infocenter 3dsystems com product library prox 100 facility guide for the most up to date facility requi...

Page 2: ...age 7 5 ATMOSPHERE REQUIREMENTS 8 Room Ventilation 8 Room Air Source 8 Room Air Exhaust 8 6 ELECTRICAL REQUIREMENTS 9 7 GAS REQUIREMENTS 9 8 COMPRESSED AIR REQUIREMENTS 10 9 WORKSTATION AND SOFTWARE R...

Page 3: ...3D SYSTEMS INC 17 CONTACT INFORMATION 16 18 FACILITY REQUIREMENTS POSTER 17...

Page 4: ...s must only be done by your 3D Systems certified Customer Support Engineer CSE during installation Attempts to install equipment or auxiliary equipment by non 3D Systems certified personnel could void...

Page 5: ...kg 2932 15 lbs Dimensions Length x Width x Height 1640 x 1010 x 2350 mm 64 57 x 39 76 x 92 52 in Process filter Weight 150 kg 330 69 lbs Dimensions Length x Width x Height 740 x 1010 x 1310 mm 29 13 x...

Page 6: ...e 5 10 L min 0 17 0 35 cubic feet per minute Purge flowrate 30 L min 1 06 cubic feet per minute Quality purity 99 99 for Nitrogen purity grade 4 8 minimum for Argon Connection on the bottom right Quic...

Page 7: ...ter replacement Physical Dimensions Dimensions H x W x D 1431 x 809 x 879 mm 56 34 x 31 85 x 34 61 in Weight 94 kg 207 23 lbs Electrical N A Mechanical Connection The filter is connected to the main c...

Page 8: ...RUWAC NA35 serie explosion proof vacuum is recommended Oxygen Monitor Supplied by Customer or 3D Systems Installed by 3D Systems For safety when working with argon you must install a room area oxygen...

Page 9: ...esiccant bags The storage period is limited to 6 months from the date of packing The printer must be stored in their original packaging in a stable position protected from impact and in a dry location...

Page 10: ...h as but not limited to oxidizers and fuels Store in a fireproof cabinet Make certain you have small containers for small quantities of powder Do not store small quantities of powder in large vessels...

Page 11: ...ERIC VARIABLES REQUIREMENTS Room temperature Heating and air conditioning installed A C not blowing directly onto the main cabinet Temperature Operating range 15 to 30 C 59 to 86 F Storage range 5 to...

Page 12: ...et The connection of the gas supply is located on the bottom right of the printer Gas ProX DMP100 Connection Type Quick coupler plug internal diameter 6mm Flow Rate Manufacturing 5 10 L min 0 17 0 35...

Page 13: ...or dental application standalone softwares By using the industry standard stl file format the manufacturing file includes a series of sliced cross sections of the part and all the manufacturing parame...

Page 14: ...fessional Ultimate Edition Windows XP 64 bit is not supported All 32 bit operating systems are not supported CPU Quad cord 64 bit processor Intel core i7 6th generation and up RAM 8 GB 16 GB or more L...

Page 15: ...Copper Beryllium CuBe2 alloys These are the only tools that are safe to use in EX zones where hazardous flammable or combustible materials are present The following items are required All electric too...

Page 16: ...tion of an inert gas system for fire suppression Although a class D is required for metal fires do not neglect to have a class ABC portable on hand as well for non metal fires that class D is not effe...

Page 17: ...tall the equipment HOW TO SUBMIT YOUR COMPLETED FACILITIES CHECKLIST Submit your completed Facility Requirements Checklist by fax mail or email to one of the 3D Systems Customer Support sites below Th...

Page 18: ...Requirements completed Electrical Requirements completed Measured 230 VAC facility power ________ VAC ________ Hz Gas Requirements completed Compressed Air Requirements completed Computer and Network...

Page 19: ...ems com www 3dsystems com NYSE DDD Customer Support Hotline US and Canada 888 598 1438 International 1 803 326 3930 UK and EMEA 44 1442 279883 Europe 33 4 73 33 45 85 Sales and Service Phone Numbers F...

Page 20: ...with your local state and federal regulations Always refer to the pipe color coding standards of your local state and federal regulations Room oxygen monitor recommended customer supplied installed s...

Page 21: ...3D SYSTEMS INC 3D Systems Inc 333 Three D Systems Circle Rock Hill SC 29730 USA www 3dsystems com 2017 3D Systems Inc All rights reserved PN 80 D47 Rev B...

Reviews: