Setting the Start Position
The
Start Position
is the position of the platform when the machine is
set up for optimal build success. The
Start Position
will need to be set
either when it’s the first time the machine has built anything or
any
of
the three conditions below are
not
met:
a.
Top of platform must be exposed
b.
Bottom of platform must be submerged
c.
The Omron Sensor must be reading 30.000
If
any one
of these conditions are
not
met, after
Move to Home
is
selected, the
Start Position
must be set.
NOTE: You should be able to see the entire platform
including all the holes . If any holes are completely
submerged and can’t be seen, the
Start Position
needs to
be set .
To Set the
Start Position
:
1.
Select
Move to Home .
Wait for elevator to home.
2.
Select
Move to Start
: The elevator will move to the default
Start
Position
.
3.
In the
Move Distance
(1) menu, select
Edit
(2).
4.
Type in the value you wish to move the platform, for example,
.1 > Set
(3).
NOTE: If at any time platform needs to be moved in the
other direction you can move it in a negative motion by
entering in the number
Value ( .1) > - > Set
. This will move
platform down instead of up .
5.
Select the
Move Distance
Button (4) from the middle of the
screen above the Stop button. Continue to move the elevator until
conditions a. and b. are met.
6.
When Platform meets conditions a. and b. stated in the steps
above, Select
Level Print Tray
(5).
7.
Ensure that all three conditions are still met:
a.
Top of platform is exposed with no material spilling out over
platform.
b.
Bottom is submerged
c.
Omron Sensor is reading 30.000.
If not, repeat
Steps 5-6
until these conditions are met.
Once the platform meets conditions a.b. and c., you must set the
Start
Position
before building. At this time select
Set Start
(6) button from
the middle panel.
NOTE: If the
Start Position
is not set, the elevator will move
to the original default
Start Position
during build .
Anytime the platform is removed and re-inserted it is advised that
Move to Start
(7) be selected and the print tray leveled to check and
make sure that all settings have been retained and platform is in
optimal building mode. If not, you will need to repeat
Steps 1-7
to
reset your
Start Position
.
NOTE: After setting the
Start Position
, there may be bubbles in the print tray . Bubbles must be removed before
building . To remove bubbles follow Removing Bubbles from next page .
a
b
c
1
2
3
4
5
6
7