30
3D Systems, Inc.
35. The LCD reminds you to wait 20 minutes for the cartridges to drain
into the tanks.
Press
CONTINUE.
36.
INSTALL THIRD SET OF CARTRIDGES
is displayed.
Install a third set of CYAN, MAGENTA, YELLOWS and CLEAR VisiJet
Spectrum C4 cartridges.
37. Although the Installation Script is now at it’s end, you are reminded
that there are additional steps that must be completed after reboot.
Close door.
Click
REBOOT
to restart the printer.
After reboot, confirm that there is no binder in the Vacuum Line on top
of the Print Head. If the line is clear, replace the cover with the four (4)
Phillips Head screws.