Console Port Pin Assignments
29
Console Port Pin Assignments
Table 4 shows the Console port pin assignments.
Cabling the Out-of-Band Management Port
You can use the 10BASE-TX port on the Switch 9300
to manage your network out-of-band. Out-of-band
management lets you diagnose network problems
easily because you manage your network from a
workstation on a different network.
To cable the out-of-band 10BASE-TX port:
1
Plug the male RJ-45 connector on the 10BASE-TX
cable into the 10BASE-TX port until it clicks into
place.
2
Attach the other end of the 10/100BASE-TX cable to
the workstation.
To configure your system to use out-of-band network
management, see your
Command Reference and the
Implementation Guide
.
Figure 13
Cabling the Out-of-Band Management Port
Table 4
Console Port Pin Assignments
Pin No.
Signal
Description
1
DCD
Data Carrier Detect
2
RDA
Received Data
3
TD
Transmitted Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request To Send
8
CTS
Clear To Send
9
–
Not used
1000 Base - LX
TX
RX
1
1000 Base - SX
10 Base - TX
1000 Base - SX
TX
RX
2
TX
RX
3
TX
RX
4
TX
RX
5
TX
RX
6
TX
RX
7
TX
RX
8
Stat
Pckt
Out-of-band
management
port
Male RJ-45 connector
10BASE-TX cable
Summary of Contents for SuperStack II Switch 9300
Page 4: ......
Page 12: ...12 ABOUT THIS GUIDE ...
Page 24: ...24 CHAPTER 2 INSTALLING THE SYSTEM ...
Page 30: ...30 CHAPTER 3 CABLING SWITCH 9300 PORTS ...
Page 50: ...50 APPENDIX B SITE REQUIREMENTS AND SAFETY CODES ...
Page 56: ...56 APPENDIX C TECHNICAL SUPPORT ...
Page 60: ...60 INDEX ...