Sample Type
— Defines the sampling method for the selected
variable and comparing the value against the thresholds. The possible
field values are:
■
Delta
— Subtracts the last sampled value from the current value.
The difference in the values is compared to the threshold.
■
Absolute
— Compares the values directly with the thresholds at
the end of the sampling interval.
■
Rising Threshold
— Displays the rising counter value that triggers
the rising threshold alarm. The rising threshold is presented on top of
the graph bars. Each monitored variable is designated a color.
■
Rising Event
— Displays the mechanism in which the alarms are
reported. The possible field values are:
■
LOG
— Indicates there is not a saving mechanism for either the
device or in the management system. If the device is not reset, the
entry remains in the Log Table.
■
TRAP
— Indicates that an SNMP trap is generated, and sent via the
Trap mechanism. The Trap can also be saved using the Trap
mechanism.
■
Both
— Indicates that both the Log and Trap mechanism are used
to report alarms.
■
Falling Threshold
— Displays the falling counter value that triggers
the falling threshold alarm.
■
Falling Event
— Displays the mechanism in which the alarms are
reported.
■
Startup Alarm
— Displays the trigger that activates the alarm
generation.
■
Rising Alarm
— Defines rising as crossing the threshold from a
low-value threshold to a higher-value threshold.
■
Falling Alarm
— Defines falling as the falling counter value that
triggers the falling threshold alarm.
■
Rising and Falling Alarm
— Both alarms are triggered
■
Interval
— Defines the alarm interval time in seconds.
■
Owner
— Displays the device or user that defined the alarm.
2
Select the
Alarm Entry
to be deleted
3
Click
. The RMON alarm is deleted, and the device is updated.
Summary of Contents for 3CRUS2475 24
Page 137: ...Defining LAG Membership 137...
Page 139: ...139 Defining Voice VLAN Defining GVRP...
Page 194: ...194 CHAPTER 9 CONFIGURING IP INFORMATION Static Indicates the ARP entry is a static entry...
Page 197: ...Defining ARP Interface Settings 197 Unchecked Maintains the current ARP entries...
Page 321: ...320 APPENDIX C TROUBLESHOOTING...
Page 329: ...328 APPENDIX GLOSSARY...