AUTO DIAGNOSTIC

Hydraulic data 

3B6

Operator Manual 

The displayed parameters are as follows:
Upper row: 

P : Main cylinder differential pressure  in Bar; 

L : Main cylinder piston side pressure in Bar; 

H : Main cylinder rod side  pressure in Bar; 

Lower row:

p : Compensation cylinder differential pressure in Bar;  

l : Compensation cylinder bottom side  pressure in Bar; 

h :Compensation cylinder rod side  pressure in Bar; 

P100  L: 50  H: 40
p  0  l:  0  h:  0

PO3

Summary of Contents for SLIM

Page 1: ...tor Operator Manual Rev 11 02 07 18 Software TXW003OPE Enter AC T a r h l S TO P Index 0 43 5 1 1 10 2 34 1 6 1 68 7055 Morning Dove Way Roscoe IL 61073 Phone 815 270 0088 www controlsystemsw com wayn...

Page 2: ...tem we recommend that you read and understand this manual before using the system WARNING For proper use of the system carefully read and understand this page MAINTENANCE The SLIM system power cable m...

Page 3: ...initial sale This warranty is in lieu of all other warranties expressed or implied and the obligation and liability of the manufacturer under this warranty shall not include any transportation or othe...

Page 4: ...em Start up Page 9 11 Range Limiting feature Slewing range limits Page 12 Virtual Wall ISAAC Page 13 14 Contrast adjustment Page 15 Language Unit of measurement Page 15 Warning Codes Page 16 Alarm mes...

Page 5: ...8 X6 X5 X4 X3 4 pole connector 4 pole connector 3 pole connector 3 pole connector 6 pole connector 6 pole connector PX0731P DTM06 4S DTM04 4P DT06 6S DTM06 2S 2 pin connector 1 0 1 SWIVEL PLATE A2BN2S...

Page 6: ...de located on top of the cylinder Rod side located inside turret area SLIM Display Mounted on outrigger swing arm A2B Switch CWT Slew potentiometer Located inside center area of turret Cable Sheave Gu...

Page 7: ...Green reference Normal operating area 0 90 capacity 3 Yellow reference Pre warning Actual load is higher than 90 of maximum capacity 4 Red reference Shut off Zone Actual load higher than 100 of maxim...

Page 8: ...etween the center of suspended load to center of turret rotation point Value feet and tenths or meters and tenths 11 WORKING CONFIGURATION Operating Mode or program selected value in feet and tenths o...

Page 9: ...on to scroll to a different operating mode or press and release the ENTER pushbutton to confirm the indicated operating mode The system will be in an inactive mode and audible visual alarms enabled un...

Page 10: ...ease the INDEX HORN pushbutton This feature is inoperable in the RIGGING TRAVEL MODE Enter AC T a r h l S TO P Index To Change the program or parts of line press and release the UP arrow pushbutton Th...

Page 11: ...ted the audible alarm sounds every 5 seconds to warn the operator the program is selected This program enables the shutoff lock out valves all the time and it is used for rigging and travel only It is...

Page 12: ...nue in that direction This feature is bypassed in Rigging and Travel mode only The lowest angle over the front is 10 degrees Warning 8 will flash on the display when the pre warning alarm is enabled 2...

Page 13: ...ate the 73 Height set position the boom at the proper height to set and press and release the ENTER pushbutton to activate that setting then press and release the INDEX pushbutton to confirm or press...

Page 14: ...deactivate the feature press and release the UP arrow pushbutton the display indicates 86 Rot Max Reset Resets the value to default value to deactivate the feature press and release the UP arrow pushb...

Page 15: ...will range from 100 130 in 5 point value changes Example 100 to 105 to 110 etc Once you have confirmed the setting the display will change back to the LMI screen Display Auto Contrast XXX To adjust th...

Page 16: ...low to rotation pot Check wiring Check harness to pot Replace pot WARNING 11 Virtual wall Angle preset limit Preset for virtual wall exceeded Increase boom angle Reset ISAAC angle setting page 14 WARN...

Page 17: ...adjustment Check Wiring from cable reel to display unit Check 12vdc supply to angle sensor Replace pot if damaged Check CAN BUS lines Call Service ALARM 4 Length Sensor 1 reading lower than minimum Po...

Page 18: ...r moisture or fluid Check connector and wiring Replace Transducer if faulty ALARM 11 Rod pressure sensor output higher than maximum Rod Pressure sensor faulty Lack of continuity in wiring Moisture in...

Page 19: ...educe SWL ALARM 64 Bypass enabled Faulty wiring System bypassed Check wiring from harness to bypass ALARM 70 Rotation pot ADC value Faulty wiring Internal fault rotation pot Check wiring from harness...

Page 20: ...Bar W Lifted load weight in Tonnes Pounds 1000 if Imperial Measurement System is used M Maximum admitted load in present position in Tonnes Pounds 1000 if Imperial Measurement System is used A Actual...

Page 21: ...inder differential pressure in Bar L Main cylinder piston side pressure in Bar H Main cylinder rod side pressure in Bar Lower row p Compensation cylinder differential pressure in Bar l Compensation cy...

Page 22: ...rence between extension1 value and extension2 value A 45 1 45 0 0 1 L 15 15 2 0 2 PO4 AUTO DIAGNOSTIC Status of Digital inputs 0 XXXX 1 XXXX 2 XXXX 3 XXXX PO5 The displayed parameters are as follows 0...

Page 23: ...as follows 4 XXXX Main cylinder piston side pressure value in Bits between 0 and 1023 5 XXXX Main cylinder rod side pressure value in Bits between 0 and 1023 6 XXXX Angle value in Bits between 0 and...

Page 24: ...cates the Input number while the lower row indicates its status The symbol means active Input the symbol means non active Input A2B 4 Bypass key switch 6 Proximity switch 7 NOTE The combination of the...

Page 25: ...when the rotation clockwise is not allowed 3 LEFT SHUT OFF It happens when the rotation counter clockwise is not allowed 4 N A 5 N A AUTO DIAGNOSTIC Digital Output Signals AUTO DIAGNOSTIC Cable Reel...

Page 26: ...on sensor 3B6 Operator Manual The displayed parameters are as follows R1 Channel 1 or A of rotation pot values between 0 to 360 degrees R2 Channel 2 or B of rotation pot values between 0 to 360 degree...

Page 27: ...n M for example if you press the button UP PLUS pushbutton you ll switch to the other type of variables if you press the button DOWN MINUS pushbutton you ll switch to the previous one The list of the...

Page 28: ...means that the value of the selected item is 1 OFF means that the value is 0 The value is also represented in the 3rd column the special page P parameter and S system variables is possible to insert...

Page 29: ...NP2 12 6 AI3 INP3 11 1 2 3 Angle Sensor A2BN2B ASA CBL3W XX WIRE COLOR SIGNAL BROWN VB GREEN WHITE VB CAN L CAN H YELLOW AN1 AGND 5V SIGNAL WHITE GREEN BROWN WIRE COLOR J8 J3 J8 J3 R 120 ohm1 4W POT 1...

Page 30: ...e Connector Cable Reel Female Connector Rotation Pot Female Connector Rotation Pot Male Connector Can Bus Female Connector DTM04 6P DTM06 6S DTM06 4S DTM04 4P DT06 6S DTM06 2S Connector Description Wh...

Reviews: