Alarm/Fault codes
17
3B6
Operator Manual
MESSAGE
CAUSE
SOLUTION
ALARM 1
Memory Data
Fault
Internal memory fault
Cycle system power, if continued
Contact Service
ALARM 2
Angle sensor 1
reading lower than
minimum
Potentiometer inside Reel is faulty.
Possible lack of continuity in wires
carrying the signals
Fault in Display unit connector
Angle out of adjustment
Check Wiring from cable reel to
Display Unit
Check 12vdc supply to angle
pot in cable reel
Replace pot if damaged
Check CAN BUS lines
Call service
ALARM 3
Angle sensor 1
reading higher
than maximum
Potentiometer inside reel is faulty.
Lack of continuity in wiring
Fault in display unit connector
Angle out of adjustment
Check Wiring from cable reel to
display unit
Check 12vdc supply to angle
sensor
Replace pot if damaged
Check CAN BUS lines
Call Service
ALARM 4
Length Sensor 1
reading lower than
minimum
Potentiometer inside reel is faulty.
Lack of continuity in wiring
Fault in display unit connector
Length out of adjustment
Check Wiring from cable reel to
display unit
Check 5 vdc supply to length
sensor
Replace pot if damaged
Adjust length pot values fully
retracted 0.250vdc
Check CAN BUS lines
Call Service
ALARM 5
Length Sensor 1
reading higher
than maximum
Potentiometer inside reel is faulty.
Lack of continuity in wiring
Fault in display unit connector
Length out of adjustment
Check Wiring from cable reel to
display unit
Check 5 vdc supply to length
sensor
Replace pot if damaged
Adjust length pot values fully
retracted 0.250 vdc
Check CAN BUS lines
Call Service