REPLACEMENT PARTS

Consumables

Item No.

Chest skin spare part

light skin 
dark skin

1024055
1024346 

Humeral IO replacement

light skin 
dark skin

1024050 
1024347

IV cannulation pad – forearm

light skin 
dark skin

1024047
1024345

IV cannulation pad – hand

light skin 
dark skin

1024048
1024344

Lung bag

1024056

Stomach bag

1024057

Carry Bag

1024318

Foam leg (right)

1024053

Foam leg (left)

1024051

Right arm (w/o IV pad)

light skin 
dark skin

1024046
1024395 

Left arm (w/o IO insert)

light skin 
dark skin

1024049
1024395 

Right foot

light skin 
dark skin

1024054
1024398

Left foot

light skin 
dark skin

1024052
1024397

Battery charge

1024326

03/2023

Operating temperature:  -10 °C up to +35 °C

Storage temperature:  -10 °C up to +35 °C

Air humidity: 

 15% - 80%

Summary of Contents for ATLAS THE ALS SIMULATOR P75

Page 1: ...ATLAS THE ALS SIMULATOR P75 USER MANUAL 1023796 1024113...

Page 2: ...Safety Instruction 5 Installation 5 Airway 6 Cardiopulmonary resuscitation CPR 8 Circulation 9 Network Router Settings 11 How to connect Atlas with REALITi360 11 How to change the Wi Fi setting on At...

Page 3: ...s for advanced life support in simulation based training and further training DELIVERY CONTENT 1 2 3 4 5 6 7 8 9 11 10 13 1 Consumable bag 2 Atlas charger 3 Tape 4 Lubricant 5 Adapter 6 IV cannulation...

Page 4: ...the monitor interface selected CPR dashboard screen for viewing all relevant parameters and values of cardiopulmonary resuscitation according to the AHA ERC Guidelines Atlas allows observation and rec...

Page 5: ...stored and charged in dry rooms Operating temperature 10 C up to 35 C Storage temperature 10 C up to 35 C Air humidity 15 80 Only use the charger provided by the manufacturer Charger connection specif...

Page 6: ...mulated dry aspiration removing inserted foreign bodies and inserting Guedel tubes OPA or Wendl tubes NPA When single assistant or dual assistant bag mask ventilation BVM is performed correctly on Atl...

Page 7: ...eal intubation Supra glottic airway alternatives like iGel Laryngeal Masks LMA and Laryngeal Tubes LT can be used in accordance with manufacturers instructions Moreover a gastric probe can be inserted...

Page 8: ...rrying out manual thoracic compressions and continuing resuscitation measures The CPR dashboard screen and Generic Defibrillator gives you feedback on the hand position With the use with of REALITi360...

Page 9: ...top of the Atlas s left arm We recommend the use of drilling systems for this procedure When performing administration of medication via the IV pad and or IO access site use a drain bag which should...

Page 10: ...and place the new training pad in the slot At the end of the training session we recommend drying removing the cannulas and taking the drainage system apart When the day s sessions are done flush the...

Page 11: ...Control iPad to the Wi Fi network Both iPads must be on the same Wi Fi network iSimulate 5 0 If the mini router PIX Link is not included in the delivery content set up the Wi Fi net work with the REA...

Page 12: ...hat appears select the corresponding REALITi monitor to your REALITi ecosystem If the monitor does not appear in the list check that the Control iPad and the Monitor iPad Pro are both con nected to th...

Page 13: ...om the main menu on the Monitor iPad 10 On the Monitor iPad Pro the monitor selected from step 9 should appear Start the defibrillator 11 Swipe in from the right screen edge of the monitor iPad show t...

Page 14: ...14 ATLAS THE ALS SIMULATOR P75 Connect Atlas with REALITi360 14 Compress the manikin You should be able to see the CPR compressions in the ECG waveform and the bar graph 13 The connected manikin will...

Page 15: ...the delivery content of Atlas 2 Connect the REALITi Monitor iPad Pro to the Wi Fi network iSimulate 5 0 If the mini router PIX Link is not included in the delivery content set up the Wi Fi network wi...

Page 16: ...e router of your choice Press the arrow button to save Please wait for 30 seconds Turn off the manikin and then power on again Now connect both iPads to the Wi Fi network of your choice The mini route...

Page 17: ...t Multiple network connections may interfere with transmissions between REALITi and Atlas Forget other networks on both your iPads beside the network required to connect with Atlas Default network is...

Page 18: ...meral IO replacement light skin dark skin 1024050 1024347 IV cannulation pad forearm light skin dark skin 1024047 1024345 IV cannulation pad hand light skin dark skin 1024048 1024344 Lung bag 1024056...

Reviews: