Illuminator HD Installation Manual V2.1.23
Page 6
© 360 Vision Technology Ltd.
Power Connections
Connect 30vdc to CON1
(Brown:- 30vdc (+), Blue:- 0vdc (-))
Ethernet Connections
Connect Ethernet cable to HD Dome connection board
using a RJ45 connector. Use colours defined in 568B
standard.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
Suitable power cables
Cable Size
360
°
IR
0.75mm²
5m
1.00mm²
10m
1.50mm²
15m
2.50mm²
25m
3.00mm²
30m
4.00mm²
40m
360
°
IR
Power Up
0.6A
Idle
(No Lamps)
0.5A
PTZ
(No Lamps)
0.6A
Idle
(IR Lamps)
5.2A
PTZ
(IR Lamps)
5.5A
Idle
(White Lamps)
TBC
PTZ
(White Lamps)
TBC
Voltage at PSU
30Vdc
Voltage at Camera
(PTZ/IR Fast tour)
27.5Vdc
Current/Voltage test at
cable length (1.5mm²)
15m
To ensure optimum Illuminator HD performance these parameters must be adhered to. Failure to do so will
invalidate the warranty.
Internal Illuminator HD Connections
The Illuminator HD connection board is located at the top of the dome.
Wall and Swan Neck mount options are supplied with 7m power and Ethernet cable. These are fitted using
cables glands.
Please note that the External Illuminator Dome is water sealed to its bracket. The Dome is supplied with
connection cables which can be cut down to any required length.
Please note that if the customer seperates the Dome from its bracket this will damage the waterproof
seals and will therefor invalidate the 3 year warranty.